Norway: industry on the ground
Norway was the eighth largest crude oil exporter and the third largest natural gas exporter in 2011, with gas exports of 99 billion cubic metres, so gas processing and export terminals are major classified-area sites.
The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, from a wet deck in the northern North Sea to a winter round on the Barents coast. This page explains what to look for in an intrinsically safe smartphone for Norway, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Norway: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Level of protection | ia, ib or ic matched to the zone | ib, for Zone 1 |
| Entity parameters | Uo, Io and Po within the device limits | Published with the certificate |
| Accessories | Chargers and cases certified with the device | Defined at certification |
| Where it applies | Norway: Stavanger and Sola, Bergen and Flesland, Kårstø | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Norway. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Norway market guide.
Norway was the eighth largest crude oil exporter and the third largest natural gas exporter in 2011, with gas exports of 99 billion cubic metres, so gas processing and export terminals are major classified-area sites.
Equinor, formed by the 2007 merger of Statoil with Norsk Hydro's oil and gas division, is headquartered in Stavanger, with the Norwegian state as its largest shareholder at 67% as of 2017.
The Kårstø complex in Rogaland processes gas and condensate from North Sea fields such as Åsgard and Sleipner, and is Europe's largest export port for natural gas liquids, with propane stored in mountain halls.
In 2024 the petroleum sector accounted for about 60% of export revenue and about 17% of GDP, so offshore installations and onshore terminals dominate the hazardous-area market.
Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.
The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.
In Norway. Rounds on a wet deck in the northern North Sea, at Hammerfest and Melkøya inside the Arctic Circle, or on a January winter round at Mongstad are long and outdoors. An intrinsically safe handheld lets an operator log findings and photograph equipment without waiting for permits. Cold hands and gloves are part of the specification conversation.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.
The market guide for Norway covers Stavanger and Sola, Bergen and Flesland, Kårstø, Kollsnes, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Norway applies ATEX through the European Economic Area agreement, and operators commonly accept IECEx as well. Offshore, each installation adds its own rules for equipment approval and for use of wireless devices. Ask the operator for the approved equipment procedure before shipping devices.
Ask which equipment marking is required, whether wireless devices need a radio permit onboard, how devices are registered and tagged, and whether English documents are accepted. Offshore installations often require pre-approval before devices are shipped by helicopter or supply vessel.
IP68 sealing and a rugged build are designed for wet and cold work, but the ambient range is fixed by the certificate, which is not yet issued and will be published with the datasheet. Compare that range with your coldest site conditions and confirm with the operator before use.
More on Norway, and on other places in Norway.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Name the site and the operator and we will send what is available before launch.