Indonesia: rules and approvals
Radio and telecom equipment certification by SDPPI is compulsory in Indonesia, with a three-year validity, local testing and a local representative required, and a marking requirement.
A Zone 1 and Zone 21 handset for Indonesian operators, mechanics, inspectors and contractor crews working across an archipelago where the nearest replacement device is often a flight away. Pertamina operates six oil refineries with a combined capacity of around 1 million barrels a day, as of 2013, and has not built a new refinery since Balongan opened in West Java in the mid-1990s. An intrinsically safe smartphone distributor in Indonesia would carry the IS-04Z1 to these buyers once certification completes.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. Indonesia has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Level of protection | ia, ib or ic matched to the zone | ib, for Zone 1 |
| Entity parameters | Uo, Io and Po within the device limits | Published with the certificate |
| Accessories | Chargers and cases certified with the device | Defined at certification |
| Where it applies | Indonesia: Dumai, Riau, Balongan, West Java, Bontang, East Kalimantan | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Indonesia. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Operators and classified areas drawn from the SAMS Indonesia market guide.
Radio and telecom equipment certification by SDPPI is compulsory in Indonesia, with a three-year validity, local testing and a local representative required, and a marking requirement.
Technical requirements for 5G devices follow Perdirgen No. 5/2021, so 5G-capable phones are tested against that rule as part of SDPPI certification.
A market-access database lists CE and FCC among other schemes recognised in Indonesia, and notes that expired certificates cannot be renewed and must be tested again as a new model.
Indonesia lies between the Indian and Pacific oceans and includes Sumatra, Java, Sulawesi and parts of Borneo and New Guinea, so field, mine and refinery sites face varied tropical conditions.
Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.
The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.
In Indonesia. From Cilacap to Bontang and Teluk Bintuni, rounds and inspections are spread across islands where a replacement device may be a flight away. An intrinsically safe handheld lets crews record and report at the point of work. That is the design intent, pending certification and local approval.
A distributor for Indonesia would carry the IS-04Z1 after certification completes; the Q4 2026 launch is the planning date and no appointment has been made. SAMS reviews applicants one by one and prefers companies with their own Ex-competent technical and service staff, since certified devices must not be repaired outside approved channels.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.
The market guide for Indonesia covers Cilacap, Central Java, Balikpapan, East Kalimantan, Dumai, Riau, Balongan, West Java, among others. Site-level pages are linked below.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for Indonesia.
SDPPI certification is compulsory for radio and telecom equipment, with local testing and a local representative required, a marking requirement and a three-year validity. Expired certificates must be tested as a new model. Confirm the current rules with SDPPI or an accredited agent before importing.
A market-access database lists CE and FCC as other recognised schemes, but also notes local testing as required for certification. Foreign reports can therefore help but may not replace testing in Indonesia, so confirm the exact approach with SDPPI or an accredited laboratory.
The market guide lists SNI, Komdigi type approval and TKDN work, together with IECEx, as in progress. None has been granted. Requirements for a given project depend on the operator and regulators, so check the current status and ask the site operator before ordering.
More on Indonesia, and on other places in Indonesia.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Name the site and the operator and we will send what is available before launch.