Ma'aden: projects and investment
Saudi Arabia estimates its mineral endowment at about 1.3 trillion US dollars, and Ma'aden is positioned as the national vehicle for exploring and developing it under Vision 2030.
Ma'aden is a Saudi state-owned mining company headquartered in Riyadh, with the Public Investment Fund as majority shareholder. Its aluminium business mines bauxite at Al Ba'itha and smelts and rolls aluminium at Ras Al Khair, producing over 1 million tonnes a year; it also produces phosphate fertiliser, gold and base metals. This page explains what to look for in an intrinsically safe mobile phone for Ma'aden, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Ma'aden: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Level of protection | ia, ib or ic matched to the zone | ib, for Zone 1 |
| Entity parameters | Uo, Io and Po within the device limits | Published with the certificate |
| Accessories | Chargers and cases certified with the device | Defined at certification |
| Where it applies | Ma'aden: Alumina refinery and aluminium smelter, Mining and processing sites, Fuel and gas handling | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Saudi Arabia. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
A short profile of its operations and the kinds of classified area that matter for portable equipment.
Ma'aden runs its own supplier portal (maaden.com/supplier-portal) where new suppliers create a supplier profile, and contractor manpower is managed through a separate Fieldglass link. Confirm current requirements with its procurement and HSE teams. The Ex certificate and an organisation's own vendor or engineering approval are two separate timelines; SAMS is working towards both and holds neither today.
Saudi Arabia estimates its mineral endowment at about 1.3 trillion US dollars, and Ma'aden is positioned as the national vehicle for exploring and developing it under Vision 2030.
Ma'aden grew from a single-mine gold producer established in 1997 into a diversified mining and processing group listed on Tadawul, with the Public Investment Fund as its main shareholder.
The Wa'ad Al-Shamal phosphate complex in northern Saudi Arabia covers mining, beneficiation, ammonia and phosphoric acid production, and finished diammonium phosphate fertiliser for export.
The aluminium chain runs from bauxite mining at Al-Ba'itha through the alumina refinery to the smelter and casthouse at Ras Al-Khair, using the Ma'aden Bauxite and Alumina and Ma'aden Aluminium companies.
Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.
The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.
In Ma'aden. Rounds at ammonia, acid and fertiliser plants, and at fuel and gas handling points, involve inspection and checklists in demanding conditions. A handheld designed for intrinsic safety could be used in those classified spots if its certificate allows. Mine and smelter areas that are not classified may not need an Ex device. That is Ma'aden's decision.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.
Ma'aden runs its own supplier portal (maaden.com/supplier-portal) where new suppliers create a supplier profile, and contractor manpower is managed through a separate Fieldglass link. Confirm current requirements with its procurement and HSE teams.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Fertiliser and aluminium complexes typically include ammonia and acid plants, fuel and gas handling, coal or fuel-fired power units, and fine process dust areas, while mines add diesel storage and blasting-related zones. Ma'aden classifies each facility, so request the area drawing, gas or dust group and temperature class.
Ma'aden and its operating subsidiaries set site HSE and electrical rules, and projects are often run through contractors who apply them. Confirm with the relevant Ma'aden business unit's procurement and HSE teams which certificates, supplier registration and permits are needed before you ship equipment.
No. Hazardous classification is limited to the parts of a site where flammable gas, vapour or dust can be present, such as ammonia, acid and fuel and gas handling areas. Ma'aden's engineers decide which areas are classified, so confirm with the site operator. The IS-04Z1 has no certificate yet.
More on Ma'aden, and on other places in Saudi Arabia.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.