Iraq: projects and investment
BP signed a preliminary agreement to develop four Kirkuk-region fields, which it estimates hold about nine billion barrels of recoverable oil, on a profit-sharing basis.
The IS-04Z1 is an intrinsically safe smartphone designed for Zone 1 and Zone 21, built for degassing stations, gas plants, refineries and terminals where a crew is a long way from a replacement. Buyers searching for an intrinsically safe cell phone supplier for Iraq can take the datasheet and the certification schedule for the IS-04Z1 now; supply follows certification.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. An intrinsically safe cell phone for Iraq cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Level of protection | ia, ib or ic matched to the zone | ib, for Zone 1 |
| Entity parameters | Uo, Io and Po within the device limits | Published with the certificate |
| Accessories | Chargers and cases certified with the device | Defined at certification |
| Where it applies | Iraq: Halfaya, Khor Al-Zubair, Rumaila | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Iraq. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Operators and classified areas drawn from the SAMS Iraq market guide.
BP signed a preliminary agreement to develop four Kirkuk-region fields, which it estimates hold about nine billion barrels of recoverable oil, on a profit-sharing basis.
In December 2024 the Iraqi Cabinet approved a Basrah to Haditha oil pipeline project valued at about 4.56 billion dollars.
Fields managed by Basra Oil Company exported about 3.23 million barrels a day from southern terminals in December 2024, nearly all of Iraq's export volume that month.
Summers from May to October are very hot and dry, with temperatures above 46 degrees Celsius, and dry dusty winds, while winters are wetter and cooler.
Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.
The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.
In Iraq. Crews at Rumaila, West Qurna and Zubair travel long distances between degassing stations, and a replacement device is far away. An intrinsically safe handheld lets operators record readings, photograph issues and report at the point of work. That is the design intent, pending certification and operator approval.
Nothing can be bought for Iraq today: the IS-04Z1 is pre-launch, and SAMS will supply end users through authorised distributors once certificates exist. What a buyer can do now is take the specification, ask for the written certification schedule and arrange a safe-area evaluation, so that the right local channel contacts you at launch.
The technical specification, marking target and conditions of use, sent by email.
Which certificates are in progress, in what order, and what is still to be confirmed.
Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.
Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.
The market guide for Iraq covers Rumaila, West Qurna, Zubair, Majnoon, among others. Site-level pages are linked below.
Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.
State oil companies run their own supplier procedures through procurement and HSE teams, and international contractors on the fields have their own. Ask the end user which company's rules apply before you ship equipment.
Yes. Iraq's Communications and Media Commission issues type approval certificates, normally valid for one year, and the process uses a registered local partner. A new certificate format with a QR code was adopted in August 2026, so check current requirements.
The IS-04Z1 is designed with IP68 sealing for industrial duty, but heat affects any battery. Ask for the datasheet's operating range and test a unit on a real summer round. Site rules on charging and storage in safe areas still apply.
More on Iraq, and on other places in Iraq.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.