Iraq: logistics and access
Fields managed by Basra Oil Company exported about 3.23 million barrels a day from southern terminals in December 2024, nearly all of Iraq's export volume that month.
The IS-04Z1 is an intrinsically safe smartphone designed for Zone 1 and Zone 21, built for degassing stations, gas plants, refineries and terminals where a crew is a long way from a replacement. If you are specifying an intrinsically safe cell phone for Iraq, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Iraq: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Level of protection | ia, ib or ic matched to the zone | ib, for Zone 1 |
| Entity parameters | Uo, Io and Po within the device limits | Published with the certificate |
| Accessories | Chargers and cases certified with the device | Defined at certification |
| Where it applies | Iraq: Rumaila, West Qurna, Zubair | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Iraq. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Iraq market guide covers.
Fields managed by Basra Oil Company exported about 3.23 million barrels a day from southern terminals in December 2024, nearly all of Iraq's export volume that month.
Summers from May to October are very hot and dry, with temperatures above 46 degrees Celsius, and dry dusty winds, while winters are wetter and cooler.
Umm Qasr is Iraq's main deep-water port, opened in July 1967, with a railway link to Basra and Baghdad.
Iraq's Communications and Media Commission issues type approval certificates valid for one year, and the application normally goes through a registered local partner.
Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.
The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.
In Iraq. Crews at Rumaila, West Qurna and Zubair travel long distances between degassing stations, and a replacement device is far away. An intrinsically safe handheld lets operators record readings, photograph issues and report at the point of work. That is the design intent, pending certification and operator approval.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.
The market guide for Iraq covers Rumaila, West Qurna, Zubair, Majnoon, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
State oil companies run their own supplier procedures through procurement and HSE teams, and international contractors on the fields have their own. Ask the end user which company's rules apply before you ship equipment.
Yes. Iraq's Communications and Media Commission issues type approval certificates, normally valid for one year, and the process uses a registered local partner. A new certificate format with a QR code was adopted in August 2026, so check current requirements.
The IS-04Z1 is designed with IP68 sealing for industrial duty, but heat affects any battery. Ask for the datasheet's operating range and test a unit on a real summer round. Site rules on charging and storage in safe areas still apply.
Related guides for Iraq and for Iraq.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Name the site and the operator and we will send what is available before launch.