Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
South Africa · industrial

Industrial Smartphone in South Africa

A Zone 1 / Zone 21 smartphone for crews at the Secunda and Sasolburg complexes, the Natref and Cape Town refineries, Mossel Bay, the fuel terminals and the surface plants of South African mining. If you are specifying an industrial smartphone for South Africa, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for South Africa, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicindustrial
DeviceSmartphone
RouteSpecification
WhereSouth Africa

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for South Africa: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · industrial

Checklist: industrial smartphone for South Africa

Checks a reviewer should make, with the IS-04Z1 position
CheckWhat to look forIS-04Z1 today
Ingress protectionIP rating for dust and waterIP68 design
Fleet managementEMM and MDM supportAndroid 16 with EMM and MDM
Explosion protectionA separate certificate and markingIn progress; not issued
Where it appliesSouth Africa: Secunda, Mpumalanga, Sasolburg, Free State, Milnerton, Cape TownClassified by the site operator
Product · South Africa

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in South Africa. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · South Africa

Where an Ex phone is used in South Africa

Operators and classified areas drawn from the SAMS South Africa market guide.

Operators, EPCs and contractors

Sasol
Synthetic fuels and chemicals at Secunda and Sasolburg
Natref
The inland refinery at Sasolburg
Astron Energy
The Cape Town refinery and fuel distribution
PetroSA
The gas to liquids complex at Mossel Bay
Transnet Pipelines
Fuel pipelines and terminals between Durban and Gauteng
Eskom
Coal-fired power stations and their coal handling plants

Industrial areas and sites

Secunda, Mpumalanga
Synthetic fuels and chemicals complex
Sasolburg, Free State
Chemicals production and the Natref refinery
Milnerton, Cape Town
The Astron Energy refinery
Mossel Bay, Western Cape
Gas to liquids complex and offshore gas
Durban
Fuel import terminals, tank farms and the chemical cluster
Richards Bay
Coal export terminal and bulk liquid storage
Field notes · South Africa

More about South Africa that matters for portable equipment

South Africa: industry on the ground

Secunda CTL, owned by Sasol, is the world's largest coal liquefaction plant, with capacity of 160,000 barrels a day from units built in 1980 and 1984, so synthetic fuel gas and liquids handling is extensive.

South Africa: geography and layout

Mining areas range from the Witwatersrand gold fields to Limpopo platinum mines such as Two Rivers at Steelpoort, so remote sites and deep underground workings are both common.

South Africa: rules and approvals

Electrical safety for some products is handled through SABS certificates of conformity and an NRCS letter of authority, which are separate from ICASA's radio approval.

South Africa: background

The 1886 discovery on the Witwatersrand started the gold rush that built Johannesburg's mining industry, and the country is still fifth in world gold production by one account.

The term · industrial

What “industrial” means for a smartphone

“Industrial” describes a phone built for plant conditions: sealed, drop-resistant and manageable at fleet scale through Android Enterprise. It does not by itself mean the phone may enter a classified area. Only a device with a valid explosion-protection certificate and marking may do that.

The IS-04Z1 is designed to be both an industrial Android phone (IP68, 4,000 mAh battery, 50 MP camera, Android 16 with EMM and MDM support) and an intrinsically safe one. Its explosion-protection certificates are in progress and have not been issued.

In South Africa. Large South African fleets cover operators such as Eskom and Transnet alongside mining and chemical contractors. EMM and MDM support lets IT control a large fleet from one console, and coverage across very large sites is part of the planning. Charging takes place in safe areas, with the battery meant to last a shift.

The route · specification

Specifying an industrial smartphone for South Africa

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · South Africa

Frequently asked questions

Can we buy an industrial smartphone in South Africa today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does an industrial smartphone in South Africa cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Is the IS-04Z1 an industrial phone as well as an Ex phone?

Yes by design: IP68 sealing, a 4,000 mAh battery, a 50 MP camera and Android 16 with EMM and MDM support. The explosion-protection certificates are separate and still in progress.

Which sites in South Africa does this cover?

The market guide for South Africa covers Secunda, Mpumalanga, Sasolburg, Free State, Milnerton, Cape Town, Mossel Bay, Western Cape, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Do mines in South Africa have different requirements from process plants?

Underground mines typically use Group I classification, with methane and coal-dust risks, while surface plants use Group II and III. SANS standards such as SANS 1515 cover mine gas-measuring equipment. Ask the mine or plant engineer which group and protection level the area drawing specifies before ordering.

Is there a national code for hazardous locations in South Africa?

Yes. The National Code of Practice for Electrical Machinery in Hazardous Locations sits under the Occupational Health and Safety Act 1993 and refers to SANS standards. Mines also have their own regulations and standards, so confirm which rules apply with the site's engineering and compliance team.

Can the IS-04Z1 be used underground in a South African mine?

No. Underground mining is equipment Group I, which is outside the scope of this device. The IS-04Z1 targets surface areas such as coal handling plants and process units using Zone 1 and Zone 21. Confirm the area and equipment group with the mine's safety officer.

Enquiry · South Africa

Ask about the IS-04Z1 for South Africa

Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.

Enquiry · South Africa

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for South Africa?

Name the site and the operator and we will send what is available before launch.