Greece: industry on the ground
Renewables and hydropower rose from over 20% to around 50% of electricity generation since 2015, while lignite fell from 60% in 2005 to about 10% in 2021.
The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, built for refinery rounds in the Attica heat, gas terminal work at Revithoussa and Alexandroupolis, and the cargo and bunker operations that run out of Piraeus. This page sets out how an industrial mobile phone supply route to Greece will work for the IS-04Z1, and what is and is not available before launch.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. An industrial mobile phone for Greece cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ingress protection | IP rating for dust and water | IP68 design |
| Fleet management | EMM and MDM support | Android 16 with EMM and MDM |
| Explosion protection | A separate certificate and marking | In progress; not issued |
| Where it applies | Greece: Revithoussa, Alexandroupolis, Aspropyrgos | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Greece. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Greece market guide.
Renewables and hydropower rose from over 20% to around 50% of electricity generation since 2015, while lignite fell from 60% in 2005 to about 10% in 2021.
The 213 km Thessaloniki-Skopje pipeline resumed operations at the beginning of 2026 after a 13-year suspension, so product pipeline terminals are active again at both ends.
A 390 MW natural gas power station in Thessaloniki opened in 2005 and is run by a subsidiary, adding gas-fired power to the refinery complex.
HelleniQ Energy operated 1,475 service stations in Greece in 2026, so fuel forecourts with classified areas are spread across the mainland and islands.
“Industrial” describes a phone built for plant conditions: sealed, drop-resistant and manageable at fleet scale through Android Enterprise. It does not by itself mean the phone may enter a classified area. Only a device with a valid explosion-protection certificate and marking may do that.
The IS-04Z1 is designed to be both an industrial Android phone (IP68, 4,000 mAh battery, 50 MP camera, Android 16 with EMM and MDM support) and an intrinsically safe one. Its explosion-protection certificates are in progress and have not been issued.
In Greece. Greek sites combine operator staff, yard workers and visiting contractors, sometimes on vessels with no other reason to call in Greece. The IS-04Z1 is designed for EMM or MDM enrolment. Charging should be in safe areas, and connectivity at quays and terminals should be checked with the site IT team.
There is no stock to order for Greece yet. The IS-04Z1 is pre-launch, certification is in progress, and supply will run through authorised distributors after the certificates are issued. Procurement teams can prepare now with the datasheet, the certification schedule and a safe-area evaluation.
The technical specification, marking target and conditions of use, sent by email.
Which certificates are in progress, in what order, and what is still to be confirmed.
Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.
Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
Yes by design: IP68 sealing, a 4,000 mAh battery, a 50 MP camera and Android 16 with EMM and MDM support. The explosion-protection certificates are separate and still in progress.
The market guide for Greece covers Aspropyrgos, Elefsina, Agioi Theodoroi, Thessaloniki, among others. Site-level pages are linked below.
Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.
Mainland refineries are reachable by road, but islands depend on ferry or air freight and timetables vary by season. Order spare batteries and chargers early, and confirm with the operator whether devices must be registered before shipment to the site.
Hot summers and direct sun can push device temperatures up, which affects battery safety and display visibility. Check the maximum ambient temperature on the certificate, and avoid leaving devices on hot surfaces. Offshore and island sites also add salt air that can affect connectors.
Shipyards and refineries may follow different regimes and have different zone definitions. A device would need a marking suitable for each area it enters. Ask each operator or yard authority what evidence and permits they require before carrying a handset in.
More on Greece, and on other places in Greece.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.