Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Mexico · industrial

Industrial Mobile Phone in Mexico

The IS-04Z1 is an Ex mobile phone for people working inside classified areas at Mexican refineries, offshore platforms, petrochemical plants and fuel terminals. This page explains what to look for in an industrial mobile phone for Mexico, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Mexico, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicindustrial
DeviceMobile Phone
RouteSpecification
WhereMexico

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Mexico: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · industrial

Checklist: industrial mobile phone for Mexico

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
Ingress protectionIP rating for dust and waterIP68 design
Fleet managementEMM and MDM supportAndroid 16 with EMM and MDM
Explosion protectionA separate certificate and markingIn progress; not issued
Where it appliesMexico: Dos Bocas, Tabasco, Bay of Campeche, Ciudad del CarmenClassified by the site operator
Product · Mexico

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Mexico. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Mexico

Where an Ex phone is used in Mexico

Operators and classified areas drawn from the SAMS Mexico market guide.

Operators, EPCs and contractors

Pemex
The national refining system, Campeche production, pipelines and terminals
CFE
Power stations and their fuel handling and storage areas
Braskem Idesa
The Etileno XXI polyethylene complex in southern Veracruz
Alpek and Indelpro
Polyester and polypropylene production on the Gulf coast
Cydsa
Chemicals and underground hydrocarbon storage in Veracruz
Vopak
Chemical and petrochemical tank terminals at Altamira and Coatzacoalcos

Industrial areas and sites

Dos Bocas, Tabasco
The Olmeca refinery, still ramping up through 2026
Bay of Campeche
Ku-Maloob-Zaap, Cantarell and the Ayatsil development
Ciudad del Carmen
The onshore base supporting the offshore fleet
Coatzacoalcos and Minatitlán
Refining and petrochemicals along the Isthmus corridor
Altamira, Tamaulipas
The leading port for petrochemical fluids in Mexico
Tula, Hidalgo
Refining and power generation on the central plateau
Field notes · Mexico

More about Mexico that matters for portable equipment

Mexico: rules and approvals

In 2025 the IFT was dissolved and replaced by the Agencia de Transformacion Digital y Telecomunicaciones, within which the Comision Reguladora de Telecomunicaciones now issues Certificates of Homologation.

Mexico: rules and approvals

Telecom and wireless products follow the PEC conformity assessment procedure, which results in a Certificate of Homologation, so older IFT references in supplier paperwork may be out of date.

Mexico: rules and approvals

Applicants are described as needing in-country testing in Mexico or at a laboratory recognised under a mutual recognition agreement, plus a local representative or importer.

Mexico: background

Pemex was formed by decree on 7 June 1938 after the nationalisation of the private oil companies, and it is still state-owned and run by the government.

The term · industrial

What “industrial” means for a smartphone

“Industrial” describes a phone built for plant conditions: sealed, drop-resistant and manageable at fleet scale through Android Enterprise. It does not by itself mean the phone may enter a classified area. Only a device with a valid explosion-protection certificate and marking may do that.

The IS-04Z1 is designed to be both an industrial Android phone (IP68, 4,000 mAh battery, 50 MP camera, Android 16 with EMM and MDM support) and an intrinsically safe one. Its explosion-protection certificates are in progress and have not been issued.

In Mexico. Contractor fleets here turn over quickly, with turnaround crews from firms such as ICA Fluor and Techint arriving and leaving at short notice. Android 16 with EMM and MDM lets a telecoms team enrol, restrict and wipe devices, with Spanish from the first screen. Charging belongs in a safe area, away from the plant fence line.

The route · specification

Specifying an industrial mobile phone for Mexico

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Mexico

Frequently asked questions

Can we buy an industrial mobile phone in Mexico today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does an industrial mobile phone in Mexico cost?

There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.

Is the IS-04Z1 an industrial phone as well as an Ex phone?

Yes by design: IP68 sealing, a 4,000 mAh battery, a 50 MP camera and Android 16 with EMM and MDM support. The explosion-protection certificates are separate and still in progress.

Which sites in Mexico does this cover?

The market guide for Mexico covers Dos Bocas, Tabasco, Bay of Campeche, Ciudad del Carmen, Coatzacoalcos and Minatitlán, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Do I need both homologation and NOM certification for a phone in Mexico?

Not always. Mexico has telecom homologation and NOM schemes, and which applies depends on the product. Radio products generally need homologation, while some electrical products also need NOM certificates for customs clearance. Confirm both requirements with a Mexican certification body before shipping.

Where does hazardous-area work concentrate in Mexico?

Typically Pemex offshore platforms in the Gulf of Mexico, onshore fields and gas processing plants, refineries such as Tula, and petrochemical complexes on the Gulf coast. Each operator issues its own classification, so request the area drawing and the gas group and temperature class before specifying equipment.

Do Mexican drawings in Clase I División 1 match a Zone 1 device?

They are different systems. Mexican practice follows the American code, so Clase and División is common, while the IS-04Z1 is designed for Zone 1 and Zone 21 and has an NEC 500 route in progress. The mapping is a documentation matter, so confirm acceptance with the unidad de verificación and the plant.

Enquiry · Mexico

Ask about the IS-04Z1 for Mexico

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Mexico

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Mexico?