Tropical climate
Hot and humid all year with about 2,350 mm of annual rain, concentrated in the monsoon periods.
The Pengerang Integrated Petroleum Complex, in the Pengerang municipality of Johor, is described as the largest petrochemical complex in Malaysia and a major petrochemical hub internationally. Heavy industry sits at Pasir Gudang, home to Johor Port with a liquid terminal, and further east at the Pengerang complex, so Zone 1 work is outside the city centre. This page explains what to look for in an IECEx mobile phone for Johor Bahru and Pasir Gudang, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Johor Bahru and Pasir Gudang: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Certificate of conformity | Number checkable on the IECEx online register | In progress; not issued |
| Standards edition | The IEC 60079 edition the certificate cites | Stated on the certificate when issued |
| Schedule of conditions | Limits of use, batteries and accessories | Published with the certificate |
| Where it applies | Johor Bahru and Pasir Gudang: Port liquid bulk terminals, Petrochemical and oleochemical plants, Refinery and petrochemical process units (Pengerang) | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Johor Bahru. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
Hot and humid all year with about 2,350 mm of annual rain, concentrated in the monsoon periods.
The Pasir Gudang estate covers about 8,000 acres and houses petrochemical, engineering and other industries, away from the city core.
Pengerang became a special local authority area in January 2017 and a municipal council in January 2020, covering about 128,830 hectares, so permits and site rules there come from a newly formed local authority.
With a 2020 population of 858,118, Johor Bahru is Malaysia's largest state capital by population, and the surrounding district is the country's second-largest by population and economy, giving a deep local labour pool.
The city forms Zone A of Iskandar Malaysia, the country's largest special economic zone by investment value, and is part of the Johor-Singapore Special Economic Zone and the Indonesia-Malaysia-Singapore Growth Triangle.
Johor Bahru has an equatorial climate with steady temperatures, daily averages between about 26 and 28 degrees Celsius, high humidity all year, around 2,350 mm of rain a year and no cyclones.
IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.
The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.
In Johor Bahru and Pasir Gudang. Because the Johor-Singapore Causeway means supply and specialist services often move between the two places, contractors serving Johor Bahru tend to work to international practice. IECEx offers a certificate of conformity plus a schedule of conditions they can read quickly. The IS-04Z1 IECEx certification is in progress; none exists yet.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.
Likely candidates are port liquid bulk terminals, petrochemical and oleochemical plants, refinery and petrochemical process units (pengerang), fuel and chemical storage. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
The best known is the Pengerang Integrated Petroleum Complex, a large petrochemical hub in southeast Johor, and there are other industrial estates across the district. Each operator classifies its own plant, so ask for zone drawings and device rules before bringing handheld equipment.
Pengerang has been a municipal council since January 2020, after becoming a local authority in 2017, within Kota Tinggi District of Johor. Plant access is controlled by each operator, so check both the municipal and plant-level induction requirements.
Rain is concentrated in the monsoon periods and humidity stays high all year. IP68 is designed to cope with water and dust, but it does not provide explosion protection. Check the certified ambient range and keep the device dry in charging areas. Ask the plant about its portable device rules.
More on Johor Bahru, and on other places in Malaysia.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Name the site and the operator and we will send what is available before launch.