Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
France · IECEx

IECEx Mobile Phone in France

The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, aimed at the refineries, chemical platforms and LNG terminals that make up the French Seveso estate. This page explains what to look for in an IECEx mobile phone for France, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for France, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicIECEx
DeviceMobile Phone
RouteSpecification
WhereFrance

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for France: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · IECEx

Checklist: IECEx mobile phone for France

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
Certificate of conformityNumber checkable on the IECEx online registerIn progress; not issued
Standards editionThe IEC 60079 edition the certificate citesStated on the certificate when issued
Schedule of conditionsLimits of use, batteries and accessoriesPublished with the certificate
Where it appliesFrance: Gonfreville-l'Orcher, Port-Jérôme, DongesClassified by the site operator
Product · France

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in France. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · France

Where this applies in France

The classified areas, operators and sites below are the ones covered in the SAMS France market guide.

Operators, EPCs and contractors

TotalEnergies
Normandy platform at Gonfreville plus Donges and Feyzin, and the Grandpuits zero-crude platform.
North Atlantic
Port-Jérôme-Gravenchon refinery and chemical plant in Normandy since 2025.
Rhône Énergies
Operates the Fos-sur-Mer refinery near Marseille since 2024.
Petroineos
Lavéra refinery and petrochemical site on the Étang de Berre.
Arkema
Specialty chemicals at Jarrie, Pierre-Bénite, Lacq and Carling.
Air Liquide
Industrial gas and hydrogen pipeline networks in Normandy and Fos.

Industrial areas and sites

Gonfreville-l'Orcher
Normandy refining and petrochemical platform beside Le Havre.
Port-Jérôme
Seine valley refinery and chemical site in Seine-Maritime.
Donges
Refinery and jetties on the Loire estuary near Saint-Nazaire.
Montoir-de-Bretagne
LNG import terminal on the same estuary.
Feyzin and the Vallée de la Chimie
Refinery and chemical plants along the Rhône south of Lyon.
Roussillon and Salaise
Chemical platform further down the Rhône corridor in Isère.
Field notes · France

More about France that matters for portable equipment

France: rules and approvals

ATEX has two equipment groups, Group I for mining and Group II for surface industries, and CE plus Ex marking lets compliant equipment be sold anywhere in the EU, including France.

France: geography and layout

Fos-sur-Mer lies about 50 km north-west of Marseille on the Mediterranean coast, west of the Etang de Berre, and hosts a major port development run by the Autonomous Port of Marseille.

France: industry on the ground

Fos-sur-Mer's port includes container terminals and a methane terminal, and its waterside industrial zone attracts steel, chemical and oil industry sites, making it a typical mixed-hazard industrial coast.

France: projects and investment

In 2022 France announced plans to build six new reactors, reversing a 2014 plan to reduce nuclear supply, which points to long-running construction and maintenance work.

The term · IECEx

What “IECEx” means for a smartphone

IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.

The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.

In France. French plateformes at Gonfreville, Fos and Lavéra bring operators together with many contractors, some of them international. For these visitors the IECEx certificate of conformity and its schedule of conditions give a common reference. IECEx certification for the IS-04Z1 is in progress, so the documents cannot be cited yet.

The route · specification

Specifying an IECEx mobile phone for France

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · France

Frequently asked questions

Can we buy an IECEx mobile phone in France today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an IECEx mobile phone in France cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Does the IS-04Z1 hold an IECEx certificate?

No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.

Which sites in France does this cover?

The market guide for France covers Gonfreville-l'Orcher, Port-Jérôme, Donges, Montoir-de-Bretagne, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Should documentation be in French for French industrial sites?

French is generally expected for instructions and safety documentation at French sites, and ATEX user instructions are typically required in the language of the destination country. International operators may also accept English. Ask the site contact which language they require for contractor equipment files.

How do nuclear outages affect device planning in France?

Large reactor outages bring many contractors at once, so site access, induction and equipment registration can be tightly scheduled. Nuclear sites also have conventional hazardous areas, for example for hydrogen and fuel stores, so agree device approval early with the plant's safety office.

Can one device be used across a shared French platform?

Zones and rules are set by the site operator and can differ between units on the same platform. A device would need a marking suitable for each zone it enters. Check the zone plan and permit rules with the platform operator before carrying a handset in.

Enquiry · France

Ask about the IS-04Z1 for France

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · France

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for France?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.