Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Malaysia · IECEx

IECEx Cell Phone in Malaysia

A Zone 1 and Zone 21 handset for Malaysian crews: process and maintenance technicians at Pengerang and Kertih, LNG operators at Bintulu, offshore production staff off Miri and Kimanis, and the safety and telecoms people who issue their equipment. If you are specifying an IECEx cell phone for Malaysia, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Malaysia, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicIECEx
DeviceCell Phone
RouteSpecification
WhereMalaysia

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Malaysia: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · IECEx

Checklist: IECEx cell phone for Malaysia

Checks a reviewer should make, with the IS-04Z1 position
CheckWhat to look forIS-04Z1 today
Certificate of conformityNumber checkable on the IECEx online registerIn progress; not issued
Standards editionThe IEC 60079 edition the certificate citesStated on the certificate when issued
Schedule of conditionsLimits of use, batteries and accessoriesPublished with the certificate
Where it appliesMalaysia: Pengerang, Johor, Kertih, Terengganu, Gebeng, PahangClassified by the site operator
Product · Malaysia

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Malaysia. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Malaysia

Hazardous-area industry in Malaysia

The main operators, industrial areas and sites that the SAMS Malaysia market guide covers.

Operators, EPCs and contractors

PETRONAS
Upstream, gas processing, refining and petrochemicals nationwide
Pengerang Refining and Petrochemical
Refinery and cracker complex at Pengerang, Johor
PETRONAS Chemicals Group
Olefins, derivatives and fertiliser at Kertih, Gebeng and Gurun
Malaysia LNG
The liquefaction complex and jetties at Bintulu, Sarawak
Sarawak Shell and Sabah Shell
Offshore oil and gas operations and their onshore support
Dialog Group
Pengerang deepwater terminals and plant maintenance services

Industrial areas and sites

Pengerang, Johor
Refinery, cracker and the deepwater storage terminals
Kertih, Terengganu
Gas processing plants and an integrated petrochemical complex
Gebeng, Pahang
Chemical plants beside Kuantan Port
Bintulu, Sarawak
LNG trains, jetties and the Samalaju heavy industry park
Miri, Sarawak
Onshore terminals, the crude oil terminal and offshore support
Kemaman, Terengganu
Supply base, fabrication yards and the oil terminal
Field notes · Malaysia

More about Malaysia that matters for portable equipment

Malaysia: rules and approvals

The Malaysian Communications and Multimedia Commission (MCMC), based in Cyberjaya, regulates communications under the Communications and Multimedia Act 1998, so radio and mobile-device rules sit with a different body from Ex rules.

Malaysia: industry on the ground

Electrical and electronic products, petroleum products, LNG, chemicals and palm-oil-based manufactures are among the main exports, so processing sites range from petrochemical units to palm-oil mills.

Malaysia: rules and approvals

Energy supply is regulated by the Energy Commission (Suruhanjaya Tenaga) and the Department of Electricity and Gas Supply, under laws that include the 1974 Petroleum Development Act and the 1993 Gas Supply Acts.

Malaysia: projects and investment

PETRONAS describes its Pengerang Integrated Complex in Johor as one of Southeast Asia's largest integrated petrochemical facilities, valued at USD 27 billion and located within the Pengerang Integrated Petroleum Complex.

The term · IECEx

What “IECEx” means for a smartphone

IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.

The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.

In Malaysia. Malaysia hosts international operators such as the Shell companies, large EPC and fabrication firms including MMHE and Sapura Energy, and contractors who rotate between sites. IECEx gives them one scheme to cite. Ask for the certificate of conformity and its schedule of conditions, which fix the marking and use limits. SIRIM and MCMC steps for the radio run separately.

The route · specification

Specifying an IECEx cell phone for Malaysia

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Malaysia

Frequently asked questions

Can we buy an IECEx cell phone in Malaysia today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does an IECEx cell phone in Malaysia cost?

There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.

Does the IS-04Z1 hold an IECEx certificate?

No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.

Which sites in Malaysia does this cover?

The market guide for Malaysia covers Pengerang, Johor, Kertih, Terengganu, Gebeng, Pahang, Bintulu, Sarawak, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Does Malaysia's climate affect which intrinsically safe phone I should choose?

Malaysia is hot and humid, so check the stated operating temperature range, ingress protection rating and battery behaviour at the top of that range. Offshore and coastal sites also add salt-laden air, which makes sealed connectors and charging contacts worth checking.

Are Petronas sites different from other Malaysian industrial sites for handheld devices?

Petronas and its operating companies typically apply their own site procedures on top of national law, including permit-to-work and device registration. Requirements vary by facility and contractor, so ask the site HSE office for its current device and induction rules.

Do I need separate approval for the radio in Malaysia?

Radio equipment is regulated separately from explosion protection. The programme lists MCMC certification through SIRIM QAS for the communications side, alongside IECEx for the hazardous area side, and both are in progress. Check with your supplier and the site operator which evidence your site requires before enrolling any device.

Enquiry · Malaysia

Ask about the IS-04Z1 for Malaysia

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Malaysia

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Malaysia?

Name the site and the operator and we will send what is available before launch.