Austria: rules and approvals
Directive 2014/34/EU became mandatory for manufacturers on 20 April 2016, and Directive 1999/92/EC requires employers to divide workplaces into zones by the likelihood and persistence of an explosive atmosphere.
The IS-04Z1 is an ex proof phone designed to ATEX 2014/34/EU for gas and dust atmospheres, built for refinery turnarounds, gas stations on the transit grid, steel works and fibre plants. If you are specifying an IECEx cell phone for Austria, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Austria: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Certificate of conformity | Number checkable on the IECEx online register | In progress; not issued |
| Standards edition | The IEC 60079 edition the certificate cites | Stated on the certificate when issued |
| Schedule of conditions | Limits of use, batteries and accessories | Published with the certificate |
| Where it applies | Austria: Schwechat, Baumgarten an der March, Linz | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Austria. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Austria market guide.
Directive 2014/34/EU became mandatory for manufacturers on 20 April 2016, and Directive 1999/92/EC requires employers to divide workplaces into zones by the likelihood and persistence of an explosive atmosphere.
More than 3,000 hydro plants provided 54% of installed generating capacity in 2021, and Verbund generates about 90% of its power from hydro, so dam and turbine-hall work dominates the electricity side.
OMV opened the Schwechat refinery near Vienna in 1960, and since 1970 the Adria-Vienna Pipeline has delivered crude from the marine terminal at Trieste, Italy, to Schwechat.
Borealis, headquartered in Vienna, is Europe's second-largest polyolefins producer and a major petrochemicals company, with plants in Austria, Germany, Belgium, Finland and Sweden.
IECEx is the international scheme for certifying equipment used in explosive atmospheres. A certificate of conformity is issued by an accredited certification body against a specific edition of the IEC 60079 standards and carries a schedule of conditions of safe use. It is not a legal requirement in most countries on its own, but many national schemes accept it as the technical basis.
The IECEx certificate for the IS-04Z1 is in progress and has not been issued. The marking target is Ex ib IIC T4, the intrinsic safety concept for Zone 1 gas with the hardest gas group (IIC) and a 135 °C temperature class.
In Austria. Inside Austria ATEX does the legal work, so IECEx matters mainly where an international operator or contractor brings its own global specification, for example a group working across OMV, Borealis or Wacker Chemie sites and non-EU plants. The certificate of conformity and schedule of conditions would then be read alongside the ATEX certificate. Both are in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
No. The IECEx certificate is in progress and has not been issued. SAMS will publish the number when it exists.
The market guide for Austria covers Schwechat, Baumgarten an der March, Linz, Donawitz and Leoben, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Chemical production, metalworking, paint and coating, food processing with dust, sewage treatment and energy supply all feature in Austria's industrial mix. Each employer must assess and zone its own workplace, so ask for the explosion protection document before bringing in new devices.
German is the working language, and ATEX instructions are typically expected in the language of the destination country. A German-language manual and certificate pack typically makes site acceptance easier. Ask the operator whether English documentation is also acceptable on its premises.
Austrian acceptance treats German documentation as a condition, so the manual, safe-use instructions and declaration of conformity are planned in German alongside English, with a German interface on Android 16. The certification programme is in progress and nothing has been issued. Check the exact requirement with your safety officer.
More on Austria, and on other places in Austria.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.