Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Germany · hazardous area

Hazardous Area Smartphone Supplier in Germany

The IS-04Z1 is an eigensicheres Smartphone designed to ATEX 2014/34/EU for Zone 1 and Zone 21, built for the chemical parks, refineries and pharmaceutical plants where most German Ex-Schutz work happens. Buyers searching for a hazardous area smartphone supplier for Germany can take the datasheet and the certification schedule for the IS-04Z1 now; supply follows certification.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Germany, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topichazardous area
DeviceSmartphone
RouteSupply
WhereGermany

Short answer. A hazardous area smartphone for Germany cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.

Current position: certification in progress, nothing issued, launch targeted for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · hazardous area

Checklist: hazardous area smartphone for Germany

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
Zone0, 1 or 2 for gas; 20, 21 or 22 for dustDesigned for Zone 1 and Zone 21
Gas groupIIA, IIB or IICIIC (target)
Area drawingThe operator's own classification drawingDecided by the site operator
Where it appliesGermany: Burghausen, Karlsruhe, LudwigshafenClassified by the site operator
Product · Germany

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Germany. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Germany

Where an Ex phone is used in Germany

Operators and classified areas drawn from the SAMS Germany market guide.

Operators, EPCs and contractors

BASF
Ludwigshafen, the largest contiguous chemical site in the world.
Currenta
Runs the Chempark sites at Leverkusen, Dormagen and Krefeld-Uerdingen.
Evonik
Chemiepark Marl and specialty chemical production.
Infraserv Höchst
Site operator for Industriepark Höchst in Frankfurt.
Wacker Chemie
Silicon and silicone production at Burghausen.
LANXESS
Specialty chemicals at Krefeld-Uerdingen and Leverkusen.

Industrial areas and sites

Ludwigshafen
BASF Verbund site, around 10 km² and roughly 200 plants.
Leverkusen
Chempark site on the Rhine shared by dozens of companies.
Marl
Chemiepark with crackers and downstream derivative plants.
Frankfurt Höchst
Industriepark shared by chemical and pharmaceutical producers.
Burghausen
Bavarian chemical triangle, refining and silicone production.
Karlsruhe
MiRO, the largest refinery in Germany, on the upper Rhine.
Field notes · Germany

More about Germany that matters for portable equipment

Germany: logistics and access

Germany imported 96% of its petroleum and 89% of its natural gas in 2025, and imports covered 65.6% of its total energy needs, so ports, pipelines and storage terminals are central.

Germany: logistics and access

Domestic hard coal production ended in 2018, so all hard coal is imported, adding port coal-handling and rail-transfer sites to Germany's dust-hazard areas.

Germany: geography and layout

Lignite is mined in the extreme west and east, mainly in North Rhine-Westphalia, Saxony and Brandenburg, and burned in plants near the mines, so dust and fuel-handling hazards cluster in those regions.

Germany: industry on the ground

In 2025 transport accounted for about 31% of energy consumption, households 28% and industry 26%, so fuel distribution and storage form a large part of the infrastructure.

The term · hazardous area

What “hazardous area” means for a smartphone

A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.

No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.

In Germany. German classified areas include chemical parks, refineries such as Karlsruhe and Schwedt, pharmaceutical plants, and LNG terminals at Wilhelmshaven and Brunsbüttel. The operator sets and documents each zone for gas and for dust. SAMS does not classify any area; the device is designed for Zone 1 and Zone 21.

The route · supply

Sourcing the IS-04Z1 for Germany

Nothing can be bought for Germany today: the IS-04Z1 is pre-launch, and SAMS will supply end users through authorised distributors once certificates exist. What a buyer can do now is take the specification, ask for the written certification schedule and arrange a safe-area evaluation, so that the right local channel contacts you at launch.

  1. 01

    Request the datasheet

    The technical specification, marking target and conditions of use, sent by email.

  2. 02

    Ask for the certification schedule

    Which certificates are in progress, in what order, and what is still to be confirmed.

  3. 03

    Evaluate in a safe area

    Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.

  4. 04

    Register for launch

    Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.

Questions · Germany

Frequently asked questions

Can we buy a hazardous area smartphone in Germany today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does a hazardous area smartphone in Germany cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Which hazardous areas is the IS-04Z1 designed for?

Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.

Which sites in Germany does this cover?

The market guide for Germany covers Ludwigshafen, Leverkusen, Marl, Frankfurt Höchst, among others. Site-level pages are linked below.

How will SAMS supply Germany?

Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.

Does Germany require ATEX for intrinsically safe phones?

Germany applies ATEX Directive 2014/34/EU for equipment and the employer-side Directive 1999/92/EC through national workplace law. Devices for Zone 1 and Zone 2 should carry CE and Ex markings with German-language instructions. Individual plants usually add their own device approval rules.

Which documents does a German buyer expect with an Ex device?

Typically the EU declaration of conformity, the ATEX or IECEx certificate, the Ex marking details and instructions in German. The operator's explosion protection document defines the zones. Provide a clear device marking photo so the site's inspector can match it to the zone.

Can contractors bring their own handsets into a chemical park?

Chemical park operators generally set contractor rules, including which devices are permitted in each zone. Requirements differ between parks. Ask the site operator about device approval, permits and registration, and about any managed-device policy, before bringing a handset to site.

Enquiry · Germany

Ask about the IS-04Z1 for Germany

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Germany

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Germany?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.