Climate
Summer highs near 44 C and occasional severe dust storms.
Riyadh is Saudi Arabia's capital and its administrative and commercial centre, with almost one-third of the country's factories. Dust storms occur in Riyadh and can cut visibility to under 10 m, so filters, port covers and sealed enclosures matter for handheld equipment. This page explains what to look for in a hazardous area smartphone for Riyadh, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Riyadh: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Zone | 0, 1 or 2 for gas; 20, 21 or 22 for dust | Designed for Zone 1 and Zone 21 |
| Gas group | IIA, IIB or IIC | IIC (target) |
| Area drawing | The operator's own classification drawing | Decided by the site operator |
| Where it applies | Riyadh: Refinery process units, Chemical and manufacturing plants, Industrial plant dust areas (Zone 21) | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Riyadh. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
Summer highs near 44 C and occasional severe dust storms.
Factories produce machinery, chemicals, construction materials, food and other goods, so hazard profiles differ by plant.
King Khalid International Airport lies about 35 km north of the city centre and is the main hub for visitors, which sets the transfer time to inland industrial areas.
The industrial cities authority MODON, set up in 2001 and headquartered in Riyadh, oversees 42 industrial cities and over 7,700 productive factories across the Kingdom.
Riyadh sits on the eastern Najd plateau beside Wadi Hanifa at an average elevation of about 600 m, so it is inland, with no sea-air corrosion unlike the coastal industrial cities.
The city had around 7 million residents in 2022, the largest population in Saudi Arabia, so contractors, service companies and specialist suppliers are concentrated here.
A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.
No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.
In Riyadh. Riyadh's classified areas include refinery process units, chemical and manufacturing plants and industrial dust areas. Most hydrocarbon sites are in the Eastern Province, not here. Each plant operator classifies its own areas, not SAMS. Obtain the classification for the specific plant first.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.
Likely candidates are refinery process units, chemical and manufacturing plants, industrial plant dust areas (zone 21). Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Rarely, but winters are cooler than many expect, with a January average low around 7 C. The bigger issue is summer heat. Check the datasheet operating range and avoid leaving devices in vehicles; the plant operator may set its own limits.
Yes. Dust storms can cut visibility to under 10 m, so a sealed device with a stated ingress protection rating and good port covers is sensible. Dust ingress and combustible dust in a plant are different issues; follow the operator's dust-zone classification for hazardous areas.
Not necessarily. Many buyers and contractors are based in Riyadh even when the classified areas are elsewhere, because most hydrocarbon sites are in the Eastern Province. Ask where the device will be used, and check the classification for that site, not for the city of purchase.
Other guides for Riyadh, other places in Saudi Arabia, and the pages behind them.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.