New Zealand: infrastructure
About 2,600 km of high-pressure gas transmission pipeline runs in the North Island, led by the 307 km Maui pipeline carrying 78% of production; there is no gas transmission in the South Island.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in New Zealand every shift: Taranaki gas-field operators, methanol and fertiliser plant crews, dairy-processing engineers managing milk-powder dust risk, and the HSE and telecoms teams who equip them. All domestic oil and gas comes from 21 petroleum permits in the Taranaki basin, with Kapuni, Maui, Pohokura and Kupe the most important fields, which concentrates upstream work on the west coast of the North Island. Distribution partners for New Zealand are being identified ahead of the Q4 2026 launch of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. New Zealand has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Zone | 0, 1 or 2 for gas; 20, 21 or 22 for dust | Designed for Zone 1 and Zone 21 |
| Gas group | IIA, IIB or IIC | IIC (target) |
| Area drawing | The operator's own classification drawing | Decided by the site operator |
| Where it applies | New Zealand: Kapuni, Marsden Point, Dairy processing sites nationwide | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in New Zealand. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS New Zealand market guide covers.
About 2,600 km of high-pressure gas transmission pipeline runs in the North Island, led by the 307 km Maui pipeline carrying 78% of production; there is no gas transmission in the South Island.
Hazardous-area inspections are done by suitably registered inspectors working to AS/NZS 60079.17 and AS/NZS 3000, with a verification dossier and records kept, so documents for any device should be easy to supply.
The Marsden Point refinery operated from 1964 to 2022 and the site now imports refined fuel, about half from South Korea and about a third from Singapore as of 2025, so tank and terminal work continues there.
Gas-based plants developed from the 1970s included an ammonia-urea plant at Kapuni, methanol at Waitara, synthetic petrol at Motunui and gas-fired power stations at New Plymouth and Huntly; confirm each site's current status.
A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.
No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.
In New Zealand. New Zealand pairs a conventional Taranaki hazard profile of gas, condensate, urea, ammonia and methanol with large-scale combustible dust risk from dairy processing. Sites include Motunui, Kapuni, Marsden Point, now a fuel import terminal, and processing plants nationwide. Each operator classifies its own areas; SAMS does not.
Distribution of the IS-04Z1 is by authorised partners only, and SAMS has not yet granted a territory for New Zealand. Each application is reviewed on its merits. Because opening a certified Ex handset in an ordinary workshop invalidates its certificate, the partner must be able to support and service the device locally.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.
The market guide for New Zealand covers Taranaki, Motunui / Waitara Valley, Kapuni, Marsden Point, among others. Site-level pages are linked below.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for New Zealand.
Electrical equipment for explosive atmospheres is generally selected and inspected to AS/NZS 60079, the local adoption of the IEC 60079 series, alongside AS/NZS 3000 for installations. IECEx certificates are widely accepted as evidence, but confirm the exact requirement with the site operator or your inspector.
Inspectors typically look for equipment marking suited to the zone, the certificate or verification dossier, and a record of inspection under AS/NZS 60079.17. Keep the certificate number, marking photo and any manufacturer instructions with the asset register entry.
The battery is sized for a working day of plant rounds, but real life depends on use of camera, GNSS and radio. There is no recharge point inside a classified area, so plan to charge in a safe area. Test the device on your own round before relying on it.
Related guides for New Zealand and for New Zealand.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Name the site and the operator and we will send what is available before launch.