Jordan: industry on the ground
In 2021 Jordan's total energy supply was 51% oil, 38% gas, 3% coal and 8% renewables, so fuel storage, gas networks and power stations form its main flammable-materials infrastructure.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in Jordan every shift: potash and phosphate plant operators, refinery crews at Zarqa, port operators at Aqaba, and the HSE and telecoms teams who equip them. The Arab Potash Company holds a concession to 2058 to extract Dead Sea minerals, has its main plants at Ghor Al Safi, and is the eighth-largest potash producer worldwide. Distribution partners for Jordan are being identified ahead of the Q4 2026 launch of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. Jordan has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Zone | 0, 1 or 2 for gas; 20, 21 or 22 for dust | Designed for Zone 1 and Zone 21 |
| Gas group | IIA, IIB or IIC | IIC (target) |
| Area drawing | The operator's own classification drawing | Decided by the site operator |
| Where it applies | Jordan: Al-Hasa and Al-Abiad, Zarqa, Aqaba | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Jordan. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Jordan market guide.
In 2021 Jordan's total energy supply was 51% oil, 38% gas, 3% coal and 8% renewables, so fuel storage, gas networks and power stations form its main flammable-materials infrastructure.
The Jordan Petroleum Refinery Company's activities include refining, filling gas cylinders, a lubricant factory and fuel marketing through JoPetrol, so one operator spans several hazardous-area process types.
A separate modernisation project with UOP and Technip aims for 73,000 barrels a day, and construction began in 2024 on a 10,000-tonne LPG storage facility intended for completion in 2026.
Aqaba, at the north-eastern tip of the Red Sea, is Jordan's only seaport and is run by the Aqaba Special Economic Zone Authority, with King Hussein International Airport nearby for equipment arrivals.
A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.
No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.
In Jordan. Jordanian classified areas include potash extraction and processing at the Dead Sea, phosphate mining and beneficiation in the south, the Zarqa refinery, fuel storage terminals and the Aqaba port zone. The operator classifies each area, not SAMS. The IS-04Z1 is designed for Zone 1 and Zone 21.
A distributor for Jordan would carry the IS-04Z1 after certification completes; the Q4 2026 launch is the planning date and no appointment has been made. SAMS reviews applicants one by one and prefers companies with their own Ex-competent technical and service staff, since certified devices must not be repaired outside approved channels.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.
The market guide for Jordan covers Dead Sea works, Eshidiya, Al-Hasa and Al-Abiad, Zarqa, among others. Site-level pages are linked below.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for Jordan.
Operators commonly work to IEC 60079 and accept ATEX or IECEx certificates, but acceptance is set by each site's own procedure. Ask the operator's HSE team for its approved equipment list and provide certificates, marking details and manufacturer instructions with your request.
The Zarqa refinery, run by the Jordan Petroleum Refinery Company, is the best-known, with refining, LPG filling and lubricants activity. Expansion and modernisation projects are planned or under way, so contractors work there. Confirm current access rules and device approvals with the company.
The market guide says Jordan's heaviest classified-area exposure is dust, at potash and phosphate sites, with gas at the refinery and Aqaba. Which applies depends on the area. Ask the operator for the zone classification, covering both dust and gas, before choosing a device.
Related guides for Jordan and for Jordan.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Name the site and the operator and we will send what is available before launch.