Jordan: projects and investment
A separate modernisation project with UOP and Technip aims for 73,000 barrels a day, and construction began in 2024 on a 10,000-tonne LPG storage facility intended for completion in 2026.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in Jordan every shift: potash and phosphate plant operators, refinery crews at Zarqa, port operators at Aqaba, and the HSE and telecoms teams who equip them. This page sets out how a hazardous area cell phone supply route to Jordan will work for the IS-04Z1, and what is and is not available before launch.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. A hazardous area cell phone for Jordan cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Zone | 0, 1 or 2 for gas; 20, 21 or 22 for dust | Designed for Zone 1 and Zone 21 |
| Gas group | IIA, IIB or IIC | IIC (target) |
| Area drawing | The operator's own classification drawing | Decided by the site operator |
| Where it applies | Jordan: Aqaba, Amman, Dead Sea works | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Jordan. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Jordan market guide covers.
A separate modernisation project with UOP and Technip aims for 73,000 barrels a day, and construction began in 2024 on a 10,000-tonne LPG storage facility intended for completion in 2026.
Aqaba, at the north-eastern tip of the Red Sea, is Jordan's only seaport and is run by the Aqaba Special Economic Zone Authority, with King Hussein International Airport nearby for equipment arrivals.
Jordan Phosphate Mines Company, founded in 1949, operates three mines and a chemical and fertiliser manufacturing complex in Aqaba, which it took over when it bought Jordan Fertilizer in 1986.
The Zarqa refinery produces about 60,000 barrels a day and a fourth expansion, contracted in 2023 to Sinopec Engineering, Technimont and Itochu, is intended to raise this to 150,000 barrels a day.
A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.
No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.
In Jordan. Jordanian classified areas include potash extraction and processing at the Dead Sea, phosphate mining and beneficiation in the south, the Zarqa refinery, fuel storage terminals and the Aqaba port zone. The operator classifies each area, not SAMS. The IS-04Z1 is designed for Zone 1 and Zone 21.
Supply of the IS-04Z1 to Jordan starts only after certification, through authorised distributors. Until then a buyer can request the datasheet and the written certification schedule, and arrange a safe-area evaluation unit, which puts the site on the list for the right local channel at launch.
The technical specification, marking target and conditions of use, sent by email.
Which certificates are in progress, in what order, and what is still to be confirmed.
Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.
Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.
The market guide for Jordan covers Dead Sea works, Eshidiya, Al-Hasa and Al-Abiad, Zarqa, among others. Site-level pages are linked below.
Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.
Yes, Aqaba is Jordan's only seaport and most imported equipment arrives there, with the airport as an alternative for urgent shipments. Customs and zone rules differ, so agree clearance procedures with your importer before ordering and allow time for road transport to Zarqa or Amman.
Summers can be very hot and dusty, so check the maximum ambient temperature on the certificate, the dust and water ingress rating and battery behaviour in heat. Avoid leaving devices in vehicles or on hot equipment, and consider sunshades for outdoor work at the refinery or solar sites.
The IS-04Z1 has IP68 sealing for dust and water, but heat affects any battery. Ask for the datasheet's temperature range and trial a unit at a desert site. Site rules on charging and storing devices in safe areas still apply.
More on Jordan, and on other places in Jordan.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.