Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Peru · hazardous area

Hazardous Area Cell Phone in Peru

The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in Peru every shift: copper mine and concentrator operators, Camisea gas-field crews, refinery engineers, and the HSE and telecoms teams who equip them. If you are specifying a hazardous area cell phone for Peru, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Peru, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topichazardous area
DeviceCell Phone
RouteSpecification
WherePeru

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Peru: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · hazardous area

Checklist: hazardous area cell phone for Peru

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
Zone0, 1 or 2 for gas; 20, 21 or 22 for dustDesigned for Zone 1 and Zone 21
Gas groupIIA, IIB or IICIIC (target)
Area drawingThe operator's own classification drawingDecided by the site operator
Where it appliesPeru: Cuajone / Toquepala, Antamina, Cerro VerdeClassified by the site operator
Product · Peru

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Peru. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Peru

Where an Ex phone is used in Peru

Operators and classified areas drawn from the SAMS Peru market guide.

Operators, EPCs and contractors

Southern Copper Corporation
Grupo México subsidiary operating Cuajone and Toquepala
Compañía Minera Antamina
BHP, Glencore, Teck and Mitsubishi joint-venture copper-zinc mine
Cerro Verde
Freeport-McMoRan copper mine near Arequipa
Las Bambas
MMG copper mine in Apurímac
Petroperú
State oil company — Talara and other refineries
Camisea consortium operators
Natural gas production in the Cusco Amazon foothills

Industrial areas and sites

Cuajone / Toquepala
Southern Copper’s high-altitude open-pit mines and smelters
Antamina
Copper-zinc mine and concentrator in Ancash
Cerro Verde
Concentrator and processing complex near Arequipa
Las Bambas
Copper mine and concentrate pipeline in Apurímac
Camisea
Gas fields and processing plant in the Cusco Amazon lowlands
Talara
Petroperú refinery on the northern coast
Field notes · Peru

More about Peru that matters for portable equipment

Peru: background

Shell discovered the Camisea fields in 1986 under blocks 38 and 42, a contract signed in 1981 that covered about 20,000 square kilometres of the southern Ucayali Basin.

Peru: geography and layout

The open pit at Cerro de Pasco is a well-known silver mine in the Andes, a reminder that much Peruvian mining takes place in mountain terrain far from the coast.

Peru: industry on the ground

In 2019 Peru was the world's second-largest producer of copper, silver and zinc, third for lead and eighth for gold, so mining is a major source of hazardous and dusty areas.

Peru: logistics and access

Camisea's remote jungle location and Andean pipeline route mean access is long and difficult, so spares, battery supplies and support for portable devices need planning in advance.

The term · hazardous area

What “hazardous area” means for a smartphone

A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.

No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.

In Peru. Peru's classified-area work runs from the high-altitude copper belt in the south, including Cuajone, Toquepala, Antamina, Cerro Verde and Las Bambas, to the Camisea gas fields in the Amazon foothills and the Talara refinery on the north coast. Operators classify their own areas, so SAMS supplies no zone drawings.

The route · specification

Specifying a hazardous area cell phone for Peru

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Peru

Frequently asked questions

Can we buy a hazardous area cell phone in Peru today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does a hazardous area cell phone in Peru cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Which hazardous areas is the IS-04Z1 designed for?

Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.

Which sites in Peru does this cover?

The market guide for Peru covers Cuajone / Toquepala, Antamina, Cerro Verde, Las Bambas, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Which Peruvian authority approves mobile phones and radios?

MTC, the Ministerio de Transportes y Comunicaciones, runs type approval for radio equipment, and a testing partner reports that it is based on FCC standards with no local laboratory tests, no local representative requirement and no extra label. Confirm current requirements with MTC or a local agent.

Where do hazardous areas arise in Peruvian gas and mining operations?

Typically at the Camisea wells and plants in the Amazon basin, the Malvinas separation plant, the Pisco terminal, refineries on the coast, and mines with diesel storage, explosives and dust. Each operator issues its own classification, so request the zone drawing and gas or dust group.

Can the device cope with altitude and UV at mine sites?

The device is designed with an outdoor-readable display and rugged sealing, but ambient and altitude limits are fixed by the certificate, which is not yet issued. Compare the published range with your mine's conditions and confirm with the operator before use at sites above 4,000 metres.

Enquiry · Peru

Ask about the IS-04Z1 for Peru

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Peru

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Peru?

Name the site and the operator and we will send what is available before launch.