China: geography and layout
China's land-based oil resources are mostly in the north, with large fields at Daqing, Shengli, Liaohe, Karamay and Dagang, so cold-climate and arid-climate sites are both common.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in China every shift: oilfield and refinery operators, coal-mining safety officers, petrochemical engineers, and the HSE and telecoms teams who equip them. If you are specifying an explosion proof smartphone for China, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for China: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Protection concept | Flameproof (Ex d) or intrinsic safety (Ex i) | Intrinsic safety, level ib |
| Zone suitability | Zone 1 gas and Zone 21 dust | Design target for Zone 1 and 21 |
| Certificate | Number, issuing body and schedule of conditions | In progress; not issued |
| Where it applies | China: Shanxi, Shaanxi and Inner Mongolia, Daqing | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in China. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS China market guide covers.
China's land-based oil resources are mostly in the north, with large fields at Daqing, Shengli, Liaohe, Karamay and Dagang, so cold-climate and arid-climate sites are both common.
The current implementing rule is CNCA-C23-01:2024, in force since 1 May 2024, and certification has been to the 2021 editions of GB/T 3836 since 1 May 2022.
GB 3836.15-2024 on design, selection and erection and GB 3836.16-2024 on inspection and maintenance took effect as mandatory national standards on 1 August 2025, governing installations rather than product certification.
Phones also need the MIIT network access licence (NAL) and SRRC radio approval; the NAL is described as compulsory, valid for three years, with local testing and a local representative required.
“Explosion proof” is the phrase most buyers use for equipment that may be taken into a classified hazardous area. Strictly, it covers several protection concepts: a flameproof enclosure (Ex d) contains an internal explosion, while intrinsic safety (Ex i) limits electrical energy so that an ignition cannot start. Phones are normally intrinsically safe, because a flameproof handset would be too heavy to carry all shift.
The IS-04Z1 uses intrinsic safety, with a marking target of Ex ib IIC T4, and is designed for Zone 1 and Zone 21. It is pre-launch, certification is in progress and no certificate has been issued.
In China. Explosion proof is the everyday phrase, but a coal mine and a coastal petrochemical plant need different thinking. Flameproof Ex d suits much fixed mining equipment; the IS-04Z1 uses intrinsic safety to limit energy in a handheld. It is designed for Zone 1 gas and Zone 21 dust, not underground classification. Operators classify areas, not SAMS.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
It is intrinsically safe (marking target Ex ib IIC T4), which is the usual way to make a phone for hazardous areas. It is not a flameproof (Ex d) design, and certification is still in progress.
The market guide for China covers Shanxi, Shaanxi and Inner Mongolia, Daqing, Shengli oilfield, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Fields such as Daqing in the north-east have cold winters, while Karamay and other north-western fields are arid, so a wide operating temperature range and dust ingress protection are sensible. Confirm site limits with the operator before deployment.
An IECEx test report is reported as recognised as test evidence, but it does not replace the CCC certificate, and ATEX certificates are not accepted. Plan a separate CCC programme with a designated body, using the IECEx test work to reduce duplication where permitted.
The design covers Zone 1 gas and Zone 21 dust together, matching the combined methane and coal dust exposure, but certification is in progress and no certificate exists. Underground mining is a distinct classification regime, so a mine operator would need to confirm suitability. Check requirements with the mine safety authority.
More on China, and on other places in China.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Name the site and the operator and we will send what is available before launch.