Bahrain: rules and approvals
The TRA released version 1.1 of its Technical Specifications Requirements for Type Approval on 30 July 2026, replacing the first edition of 27 February 2024, so documents prepared earlier should be checked.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in Bahrain every shift: refinery and gas-plant operators, smelter potroom crews, inspection engineers and the HSE and telecoms teams who equip them. Buyers searching for an explosion proof cell phone supplier for Bahrain can take the datasheet and the certification schedule for the IS-04Z1 now; supply follows certification.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. An explosion proof cell phone for Bahrain cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Protection concept | Flameproof (Ex d) or intrinsic safety (Ex i) | Intrinsic safety, level ib |
| Zone suitability | Zone 1 gas and Zone 21 dust | Design target for Zone 1 and 21 |
| Certificate | Number, issuing body and schedule of conditions | In progress; not issued |
| Where it applies | Bahrain: Al Dur and Al Ezzel, Bahrain Investment Wharf, Sitra | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Bahrain. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Operators and classified areas drawn from the SAMS Bahrain market guide.
The TRA released version 1.1 of its Technical Specifications Requirements for Type Approval on 30 July 2026, replacing the first edition of 27 February 2024, so documents prepared earlier should be checked.
Bahrain covers about 694 square kilometres, with Bahrain Island making up roughly 78 percent. It lies about 24 km off the Saudi coast and 28 km from Qatar.
Mina Salman is Bahrain's primary cargo port and customs point, covering 80 hectares since 1962, and more than 75 percent of its cargo is containerised.
Bapco was founded in 1929, found the first oil field in the Gulf outside Iran in 1932 and built the first Gulf refinery outside Iran in 1936, so some plant is very old.
“Explosion proof” is the phrase most buyers use for equipment that may be taken into a classified hazardous area. Strictly, it covers several protection concepts: a flameproof enclosure (Ex d) contains an internal explosion, while intrinsic safety (Ex i) limits electrical energy so that an ignition cannot start. Phones are normally intrinsically safe, because a flameproof handset would be too heavy to carry all shift.
The IS-04Z1 uses intrinsic safety, with a marking target of Ex ib IIC T4, and is designed for Zone 1 and Zone 21. It is pre-launch, certification is in progress and no certificate has been issued.
In Bahrain. At Sitra, Askar and Hidd the phrase explosion proof often means flameproof Ex d equipment. A handheld in a refinery tank farm or a potline area is a different case, and the IS-04Z1 uses intrinsic safety to limit energy. The refinery gas areas and the smelter dust areas are classified by the operators, not SAMS.
There is no stock to order for Bahrain yet. The IS-04Z1 is pre-launch, certification is in progress, and supply will run through authorised distributors after the certificates are issued. Procurement teams can prepare now with the datasheet, the certification schedule and a safe-area evaluation.
The technical specification, marking target and conditions of use, sent by email.
Which certificates are in progress, in what order, and what is still to be confirmed.
Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.
Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
It is intrinsically safe (marking target Ex ib IIC T4), which is the usual way to make a phone for hazardous areas. It is not a flameproof (Ex d) design, and certification is still in progress.
The market guide for Bahrain covers Sitra, Askar, Hidd, Awali, among others. Site-level pages are linked below.
Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.
Yes. Telecommunications equipment imported into Bahrain is subject to TRA type approval, and a certificate normally lasts three years. The application is made through a Bahraini supplier, and the TRA has just released version 1.1 of its technical specifications, so check current requirements.
The country is about 694 square kilometres and Bahrain Island is only 48 km long, so Manama is within short road distance of Sitra and the main industrial areas. Site access, not distance, is usually the planning constraint.
Photography often runs on permit at Bahraini sites. Android 16 with EMM and MDM lets the camera policy and corporate profile be set centrally, so the camera can be restricted or allowed per site. The 50 MP camera is a feature, not a right of use. Check the permit rules with the site operator.
Related guides for Bahrain and for Bahrain.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.