Seatrium yards
Seatrium lists Singapore yards at Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard, with headquarters at 80 Tuas South Boulevard.
Seatrium's Singapore yards include Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard, plus the offshore-focused Crescent and Pandan yards, so contractors may work at several sites in one project. Repair, conversion and newbuild work on tanks, cargo spaces and paint areas creates Zone 1 conditions. If you are specifying an Ex-proof mobile phone for Keppel Shipyard (now Seatrium yards), Singapore, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Keppel Shipyard (now Seatrium yards), Singapore: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Keppel Shipyard (now Seatrium yards), Singapore: Vessel tank and cargo spaces, Offshore unit conversion, Paint and solvent areas | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Keppel Shipyard. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
Seatrium lists Singapore yards at Admiralty, Benoi, Pioneer, Tuas and Tuas Boulevard, with headquarters at 80 Tuas South Boulevard.
Seatrium describes itself as formed from the 2023 merger of Sembcorp Marine and Keppel Offshore & Marine, so older descriptions of Keppel-run yards are out of date.
Keppel privatised its offshore and marine business in 2001, and in 2002 combined Keppel Shipyard with Keppel FELS and Keppel Singmarine to form the Keppel Offshore and Marine group.
Seatrium, formed in 2023, groups its work into oil and gas newbuilds and conversions, renewables and new energies, specialised shipbuilding, and repairs and upgrades.
Repair and upgrade scope at the Singapore yards covers gas carriers (LNG and LPG), floating production units, jack-ups and semi-submersibles, and jumboisation or dejumboisation, each with different tank and gas-freeing routines.
Singapore has an equatorial climate with steady heat, high humidity and frequent afternoon rain, so outdoor yard work exposes handheld equipment to moisture and sun throughout the year.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Keppel Shipyard (now Seatrium yards), Singapore. Vessel tanks, paint and solvent areas and FPSO conversion work involve solvent vapour and fuel residues, so a marking check should read the gas group and temperature class from the vessel's gas-free or hazard assessment. The IS-04Z1 target marking is II 2 G Ex ib IIC T4, still a target.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
Likely candidates are vessel tank and cargo spaces, offshore unit conversion, paint and solvent areas, dry dock work. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Conversion projects involve large process and tank systems that become classified areas when commissioned, while repair work is more tank-by-tank and short term. Expect tighter control of electronics on conversion hulls close to hydrocarbon systems. The vessel owner and yard HSE team set the rules for each project.
Keppel's offshore and marine yards are now part of Seatrium, formed in 2023 from Sembcorp Marine and Keppel Offshore and Marine. Former Keppel yard sites in Singapore are now listed under Seatrium, so use that name when registering for contractor access or supplier approval.
No. Seatrium was formed in 2023 and Keppel's yards now operate under it, and the Gul yard was sold to ST Engineering. Use current names when contacting yards. Details of individual Seatrium yards were not verified, so ask the company which yard serves your project.
Other guides for Keppel Shipyard, other places in Singapore, and the pages behind them.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Name the site and the operator and we will send what is available before launch.