New Zealand: people and language
Hazardous-area inspections are done by suitably registered inspectors working to AS/NZS 60079.17 and AS/NZS 3000, with a verification dossier and records kept, so documents for any device should be easy to supply.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in New Zealand every shift: Taranaki gas-field operators, methanol and fertiliser plant crews, dairy-processing engineers managing milk-powder dust risk, and the HSE and telecoms teams who equip them. AS/NZS 60079 is the Australia and New Zealand adoption of the IEC 60079 series, covering classification, selection, installation, inspection and repair of electrical equipment in explosive atmospheres. Distribution partners for New Zealand are being identified ahead of the Q4 2026 launch of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. New Zealand has no appointed SAMS distributor yet: the IS-04Z1 is pre-launch (certification in progress, no certificate issued, launch planned for Q4 2026), and distributor applications are open.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | New Zealand: Motunui / Waitara Valley, Kapuni, Marsden Point | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in New Zealand. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS New Zealand market guide.
Hazardous-area inspections are done by suitably registered inspectors working to AS/NZS 60079.17 and AS/NZS 3000, with a verification dossier and records kept, so documents for any device should be easy to supply.
The Marsden Point refinery operated from 1964 to 2022 and the site now imports refined fuel, about half from South Korea and about a third from Singapore as of 2025, so tank and terminal work continues there.
Gas-based plants developed from the 1970s included an ammonia-urea plant at Kapuni, methanol at Waitara, synthetic petrol at Motunui and gas-fired power stations at New Plymouth and Huntly; confirm each site's current status.
The Alpha well drilled at New Plymouth in 1865 was the first oil well in the Commonwealth; later gas from Kapuni (1970) and Maui (1978) supported large gas-based industrial plants.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In New Zealand. A marking check in New Zealand reads II 2 G Ex ib IIC T4 against the area classification for Taranaki gas, condensate and methanol work. The second hazard is combustible dust: dried milk powder in drying towers and silos at Fonterra and other processors, which is why the Zone 21 design target matters and should be compared with each site's drawing.
Distribution of the IS-04Z1 is by authorised partners only, and SAMS has not yet granted a territory for New Zealand. Each application is reviewed on its merits. Because opening a certified Ex handset in an ordinary workshop invalidates its certificate, the partner must be able to support and service the device locally.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
The market guide for New Zealand covers Taranaki, Motunui / Waitara Valley, Kapuni, Marsden Point, among others. Site-level pages are linked below.
Apply through the distributor page with your company details and the territory you cover. SAMS reviews applications company by company and has not yet granted a territory for New Zealand.
Most Ex devices arrive by sea or air freight, and the North Island holds nearly all the gas network, so lead times to Taranaki or Auckland differ from the South Island. Plan spare batteries and accessories in country, and confirm local after-sales support before ordering.
Mainly in Taranaki, where all domestic oil and gas is produced, along the North Island gas pipeline network, at Ahuroa gas storage, and at fuel import terminals such as Marsden Point. Site permits and induction rules differ by operator, so check before arrival.
Dried milk powder is a well-documented combustible dust, and drying towers and storage silos are classified accordingly. The IS-04Z1 is designed for Zone 21 as well as Zone 1, but certification is in progress. Confirm the zone and dust group with the site operator before use.
Other guides for New Zealand, other places in New Zealand, and the pages behind them.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Name the site and the operator and we will send what is available before launch.