Netherlands: who works there
Rotterdam has five port concessions, operated by separate companies under the overall authority of the port, so access, induction and device rules typically differ from terminal to terminal.
The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, aimed at the refineries, chemical parks and tank terminals between Rotterdam and Geleen. If you are specifying an Ex-proof cell phone for Netherlands, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Netherlands: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | Netherlands: Pernis, Botlek, Europoort | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Netherlands. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Netherlands market guide covers.
Rotterdam has five port concessions, operated by separate companies under the overall authority of the port, so access, induction and device rules typically differ from terminal to terminal.
In 2020, 64.2% of Dutch power came from gas-fired thermal stations, and the last of fourteen gas power stations was commissioned in 2013, so gas plant maintenance is a recurring workload.
The Port of Rotterdam is Europe's largest seaport, covering 105 square kilometres over about 40 km, from the historic harbours through Botlek and Europoort to the reclaimed Maasvlakte on the North Sea.
The port of Amsterdam handled 63 million tonnes of cargo in 2023, is the second largest port in the Netherlands, and comprises 620 hectares of waterways and 1,995 hectares of land along the North Sea Canal.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In Netherlands. A marking check in the Netherlands compares II 2 G Ex ib IIC T4 with the explosieveiligheidsdocument. The IIC group covers the hydrogen on the Rotterdam cluster and the national network under construction. Dust is the other half: ammonia and fertiliser at Sluiskil and powder at Chemelot make the Zone 21 target relevant, with each zone and class confirmed.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
The market guide for Netherlands covers Pernis, Botlek, Europoort, Maasvlakte, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
The Rhine-Meuse delta coast is windy and often wet, so check the water ingress rating, glove-friendly touch and cold-temperature battery performance. Terminals have separate induction processes, so plan device registration with each concession's HSE team in advance.
Petrochemical and refinery sites are concentrated at Botlek and Europoort and in the area west of the city, with further bulk terminals at Maasvlakte. Exact classifications are held by each concession holder, so request the zoning drawings for your terminal.
Camera policy is a site decision. Android 16 with EMM and MDM allows the camera, location services and apps to be restricted centrally, which lets a telecoms team show what is permitted. Hold the evidence for the site's security and HSE teams before bringing any device through the gate.
More on Netherlands, and on other places in Netherlands.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.