North Oil Company: industry on the ground
Kirkuk is reported to have three pay zones, with the Tertiary reservoir holding about 98 per cent of recoverable reserves, so production is concentrated in a small number of formations.
North Oil Company is a state-owned Iraqi company under the Ministry of Oil, headquartered in Kirkuk. The development and production contract covers an initial recovery of more than 3 billion barrels of oil equivalent from the Baba and Avanah domes of Kirkuk and the Bai Hassan, Jambur and Khabbaz fields. Buyers searching for an ATEX and IECEx smartphone supplier for North Oil Company can take the datasheet and the certification schedule for the IS-04Z1 now; supply follows certification.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. An ATEX and IECEx smartphone for North Oil Company cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | North Oil Company: Oil production facilities, Gas plants, Pipeline stations | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Iraq. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main sites and the hazardous-area types a portable device is likely to meet at this organisation.
Supplier registration and equipment approval are run by the organisation itself; confirm current requirements with its procurement and HSE teams. The Ex certificate and an organisation's own vendor or engineering approval are two separate timelines; SAMS is working towards both and holds neither today.
Kirkuk is reported to have three pay zones, with the Tertiary reservoir holding about 98 per cent of recoverable reserves, so production is concentrated in a small number of formations.
The contract covers rehabilitation, redevelopment and optimisation of producing fields, so work is brownfield, with new equipment installed beside operating plant.
North Oil Company is one of 16 companies owned by Iraq's Ministry of Oil and is headquartered in Kirkuk, with a licence area running from the northern border down to the 32.5th parallel, just south of Baghdad.
bp's contractor company for Kirkuk has agreed terms for ConocoPhillips to take 42 per cent, subject to approvals, so contractor and supplier arrangements may change during 2026.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In North Oil Company. A reviewer at North Oil Company would expect certificate evidence before a handheld enters the Kirkuk, Bai Hassan, Jambur or Khabbaz facilities. With a redevelopment contract signed with bp in 2025, international contractors and EPCs are likely to work alongside the company, so a dual ATEX and IECEx route can serve both sets of paperwork. IS-04Z1 certification is in progress; no certificate exists.
Nothing can be bought for North Oil Company today: the IS-04Z1 is pre-launch, and SAMS will supply end users through authorised distributors once certificates exist. What a buyer can do now is take the specification, ask for the written certification schedule and arrange a safe-area evaluation, so that the right local channel contacts you at launch.
The technical specification, marking target and conditions of use, sent by email.
Which certificates are in progress, in what order, and what is still to be confirmed.
Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.
Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.
Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
Supplier registration and equipment approval are run by the organisation itself; confirm current requirements with its procurement and HSE teams.
Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.
Possibly. bp's contractor company has agreed terms for ConocoPhillips to hold 42 per cent, subject to approvals, although the framework and the operators' role do not change. Equipment approvals typically stay with the operating company, so ask the operator and the main contractor.
Iraq's Communications and Media Commission handles type approval, usually through a locally registered partner, following EU-style compliance procedures. Confirm current requirements before shipping, and also ask the operator about security vetting and site rules for personal and portable electronic devices.
Only if its protection suits the zone and gas group of the specific location. A phone designed around intrinsic safety, with a marking such as the IS-04Z1 target, would be assessed against the operator's drawings. Seek the area classification from North Oil Company first; certification for the IS-04Z1 is in progress.
More on North Oil Company, and on other places in Iraq.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.