Port
Ras Laffan Port encloses a water area of about 4,500 hectares and handles LNG and other liquid exports.
Ras Laffan Industrial City lies about 80 km north of Doha and is administered by QatarEnergy. It is Qatar's main site for liquefied natural gas and gas-to-liquids production, so Zone 1 gas areas are widespread across plants and the port. If you are specifying an ATEX and IECEx smartphone for Ras Laffan Industrial City, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Ras Laffan Industrial City: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | Ras Laffan Industrial City: LNG production trains and storage, Gas processing, Gas-to-liquids plants | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Ras Laffan. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The companies on site and the hazardous-area types a handset is likely to meet there.
Ras Laffan Port encloses a water area of about 4,500 hectares and handles LNG and other liquid exports.
The industrial city was commissioned in 1996 to host facilities processing gas from the North Field.
Ras Laffan and neighbouring Fuwayrit hold about 30 per cent of Qatar's sea turtle nests, so environmental rules around lighting and site works can apply to contractors.
Qatar's Communications Regulatory Authority is consulting on class licensing for short-range devices, which matters for Bluetooth and Wi-Fi accessories used with handsets on site.
The Ras Laffan Emergency and Safety College, opened in 2013 on about 100 hectares, trains fire, rescue and hazardous-materials staff for the oil, gas and petrochemical sectors.
Planned industrial land at Ras Laffan was raised from about 106 to 296 square km in 2004, so the estate is large and plants are spread over long distances.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In Ras Laffan Industrial City. At Ras Laffan, reviewers from QatarEnergy LNG, the GTL plants and Dolphin Energy would expect certificate evidence to match the Zone 1 gas areas of the LNG trains and processing units. A dual ATEX and IECEx route is helpful where international contractors work across several plants. The IS-04Z1 has no certificate yet; certification is in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
Likely candidates are lng production trains and storage, gas processing, gas-to-liquids plants, refinery process units. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
It is an industrial city of about 296 square km planned area, with separate LNG, gas-to-liquids, refinery, power and port operators. Each operator typically controls its own permits and equipment approvals, so confirm the rules with the plant you are visiting.
Often yes, but short-range device rules are set by Qatar's Communications Regulatory Authority, which has been consulting on class licences. Plant operators may also restrict Bluetooth or Wi-Fi in some areas, so confirm both points before relying on accessories.
Radio and telecommunications terminal equipment in Qatar falls under type approval from the Communications Regulatory Authority. This is separate from explosion-protection certification. A buyer should ask the supplier for both sets of documents, and check with the plant operator whether additional site-level approval is required.
More on Ras Laffan, and on other places in Qatar.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.