Dispersed fields
Rumaila lies roughly 50 km south-west of Basra and other fields are further out, so crews travel long distances between sites.
Basra is Iraq's southern oil hub and the base of the Basra Oil Company. Super-giant onshore fields such as Rumaila and Majnoon lie in the governorate, and most crude is exported through the Al Basrah Oil Terminal, so Zone 1 work is routine across the area. If you are specifying an ATEX and IECEx smartphone for Basra, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Basra: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | Basra: Degassing and gathering stations, Wellheads and flowlines, Gas processing plants | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Basra. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Who operates there and which kinds of classified area a handset would meet, from the SAMS site research.
Rumaila lies roughly 50 km south-west of Basra and other fields are further out, so crews travel long distances between sites.
Summer temperatures regularly exceed 50 C with humidity that can pass 90 per cent, which affects device thermal limits and battery life.
The city is consistently one of the hottest on the planet, with summer temperatures regularly above 50 degrees Celsius, so heat management is a safety factor for outdoor work.
Southern terminals exported about 3.23 million barrels a day in December 2024, so tank farms, pump stations and metering systems are heavily used.
Basra Oil Company, headquartered in Basra, handles exploration, drilling, production, storage and export in the south and was previously known as the Iraqi South Oil Company.
Umm Qasr, Iraq's main deep-water port, opened in July 1967 and is linked by railway to Basra and Baghdad.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In Basra. Basra's large field operators and joint operating organisations bring in international contractors, and their reviewers usually look for both ATEX and IECEx documents when approving a handheld for degassing stations and gas plants. A dual route lets one device file serve different EPC and operator checklists. The IS-04Z1 has no certificate yet, as certification is in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
Likely candidates are degassing and gathering stations, wellheads and flowlines, gas processing plants, crude storage and export terminals. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Summer temperatures regularly exceed 50 degrees Celsius, with high humidity near the coast. Devices should have a wide operating temperature range, and teams need heat plans for outdoor work.
Umm Qasr is Iraq's main deep-water port and is linked to Basra by railway; projects such as the Grand Faw Port are changing logistics in the area. Plan for customs and escort procedures with the operator's logistics team.
High ambient temperature shortens battery life and can limit the temperature range allowed on the certificate. Keep the phone out of direct sun, carry a spare charged in a safe area and read the permitted ambient range once the IS-04Z1 certificate exists. Confirm site rules with the operator.
More on Basra, and on other places in Iraq.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.