Finland: who works there
Neste was founded in 1948 as the state petrol company and was the third largest Finnish company by revenue in 2021, with the Finnish state holding 35.91% of shares in 2022.
The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, built for the refinery and polymer plants at Kilpilahti, the metal and chemical parks on the Bothnian coast and the mill and mine sites where a winter round is measured in kilometres. This page sets out how an ATEX and IECEx mobile phone supply route to Finland will work for the IS-04Z1, and what is and is not available before launch.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. An ATEX and IECEx mobile phone for Finland cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.
For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | Finland: Sotkamo, Äänekoski, Kilpilahti, Porvoo | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Finland. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS Finland market guide covers.
Neste was founded in 1948 as the state petrol company and was the third largest Finnish company by revenue in 2021, with the Finnish state holding 35.91% of shares in 2022.
Neste built Finland's first refinery at Naantali in 1957 and the Porvoo refinery at Sköldvik (Kilpilahti) in 1965, so Naantali and Porvoo are the traditional centres of refining.
Finland lacks domestic fossil energy and imports substantial petroleum and natural gas, so refining, fuel terminals and gas-supply sites are mostly import-led rather than field-based.
The industrial sector accounted for 53% of total final energy consumption in 2021, well above the IEA average, so process industry sites strongly shape the demand for classified-area equipment.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In Finland. A Finnish procurement or HSE reviewer at Kilpilahti or a pulp mill would expect ATEX evidence under the national implementation of the directive. IECEx documents alongside would serve contractors arriving from other countries. A dual route lets one evidence pack support both the site review and visiting turnaround crews. Certification is in progress and no certificate has been issued.
Nothing can be bought for Finland today: the IS-04Z1 is pre-launch, and SAMS will supply end users through authorised distributors once certificates exist. What a buyer can do now is take the specification, ask for the written certification schedule and arrange a safe-area evaluation, so that the right local channel contacts you at launch.
The technical specification, marking target and conditions of use, sent by email.
Which certificates are in progress, in what order, and what is still to be confirmed.
Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.
Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
The market guide for Finland covers Kilpilahti, Porvoo, Naantali, Kokkola, Harjavalta, among others. Site-level pages are linked below.
Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.
Finland is an EU member, so ATEX Directive 2014/34/EU applies to equipment placed on the market and employers zone workplaces under Directive 1999/92/EC. Operators usually also apply their own permit and device registration processes. Ask the site safety office for its current list.
Neste built refineries at Naantali in 1957 and at Porvoo, in the Kilpilahti area, in 1965. Fuel terminals and gas-supply sites serve the rest of the country. Individual site rules and current operations should be confirmed with the operator before a visit.
The IS-04Z1 is designed for industrial duty with IP68 sealing, but cold performance of any lithium battery needs testing. Ask for the datasheet's operating temperature range and trial a unit on an actual winter round. Site rules on charging and storage in safe areas still apply.
Other guides for Finland, other places in Finland, and the pages behind them.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.