Finland · ATEX and IECEx

ATEX and IECEx Mobile Phone in Finland

The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, built for the refinery and polymer plants at Kilpilahti, the metal and chemical parks on the Bothnian coast and the mill and mine sites where a winter round is measured in kilometres. This page explains what to look for in an ATEX and IECEx mobile phone for Finland, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Finland, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceMobile Phone
RouteSpecification
WhereFinland

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Finland: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx mobile phone for Finland

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesFinland: Kilpilahti, Porvoo, Naantali, KokkolaClassified by the site operator
Product · Finland

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Finland. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Finland

Where an Ex phone is used in Finland

Operators and classified areas drawn from the SAMS Finland market guide.

Operators, EPCs and contractors

Neste
Porvoo refinery and renewable fuel production at Kilpilahti and Naantali.
Borealis Polymers
Cracker and polyolefin production inside the Kilpilahti area.
Kemira
Process and pulp chemicals at Oulu, Joutseno and Äetsä.
Terrafame
Nickel, zinc and battery chemical production at Sotkamo in Kainuu.
Boliden Kokkola
Zinc smelting and processing in the Kokkola industrial park.
Yara Suomi
Fertiliser and nitrogen chemical plants at Uusikaupunki and Siilinjärvi.

Industrial areas and sites

Kilpilahti, Porvoo
Refinery, cracker, polymer plants and chemical park behind one perimeter.
Naantali
Coastal refining and terminal operations near Turku.
Kokkola
Large chemical and metals industrial park on the Bothnian coast.
Harjavalta
Copper, nickel and battery material processing in Satakunta.
Sotkamo
Metal and battery chemical production in the Kainuu region.
Äänekoski
Bioproduct mill with recovery boiler, lime kiln and wood dust areas.
Field notes · Finland

More about Finland that matters for portable equipment

Finland: who works there

Neste was founded in 1948 as the state petrol company and was the third largest Finnish company by revenue in 2021, with the Finnish state holding 35.91% of shares in 2022.

Finland: background

Neste built Finland's first refinery at Naantali in 1957 and the Porvoo refinery at Sköldvik (Kilpilahti) in 1965, so Naantali and Porvoo are the traditional centres of refining.

Finland: industry on the ground

Finland lacks domestic fossil energy and imports substantial petroleum and natural gas, so refining, fuel terminals and gas-supply sites are mostly import-led rather than field-based.

Finland: industry on the ground

The industrial sector accounted for 53% of total final energy consumption in 2021, well above the IEA average, so process industry sites strongly shape the demand for classified-area equipment.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Finland. A Finnish procurement or HSE reviewer at Kilpilahti or a pulp mill would expect ATEX evidence under the national implementation of the directive. IECEx documents alongside would serve contractors arriving from other countries. A dual route lets one evidence pack support both the site review and visiting turnaround crews. Certification is in progress and no certificate has been issued.

The route · specification

Specifying an ATEX and IECEx mobile phone for Finland

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Finland

Frequently asked questions

Can we buy an ATEX and IECEx mobile phone in Finland today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does an ATEX and IECEx mobile phone in Finland cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which sites in Finland does this cover?

The market guide for Finland covers Kilpilahti, Porvoo, Naantali, Kokkola, Harjavalta, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Does Finland follow ATEX for handheld devices in hazardous areas?

Finland is an EU member, so ATEX Directive 2014/34/EU applies to equipment placed on the market and employers zone workplaces under Directive 1999/92/EC. Operators usually also apply their own permit and device registration processes. Ask the site safety office for its current list.

Where are Finland's main refining and fuel sites?

Neste built refineries at Naantali in 1957 and at Porvoo, in the Kilpilahti area, in 1965. Fuel terminals and gas-supply sites serve the rest of the country. Individual site rules and current operations should be confirmed with the operator before a visit.

Can a phone be used in cold Finnish winter conditions?

The IS-04Z1 is designed for industrial duty with IP68 sealing, but cold performance of any lithium battery needs testing. Ask for the datasheet's operating temperature range and trial a unit on an actual winter round. Site rules on charging and storage in safe areas still apply.

Enquiry · Finland

Ask about the IS-04Z1 for Finland

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Finland

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Finland?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.