Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Czech Republic · ATEX and IECEx

ATEX and IECEx Mobile Phone in Czech Republic

The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, built for Czech refineries, chemical plants, tank farms and coke ovens rather than for a catalogue. If you are specifying an ATEX and IECEx mobile phone for Czech Republic, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Czech Republic, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceMobile Phone
RouteSpecification
WhereCzech Republic

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Czech Republic: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx mobile phone for Czech Republic

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesCzech Republic: Litvínov and Záluží, Kralupy nad Vltavou, NeratoviceClassified by the site operator
Product · Czech Republic

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Czech Republic. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Czech Republic

Where this applies in Czech Republic

The classified areas, operators and sites below are the ones covered in the SAMS Czech Republic market guide.

Operators, EPCs and contractors

Orlen Unipetrol
Litvínov and Kralupy refineries and the Záluží petrochemical complex.
Spolana
PVC production at Neratovice.
Synthos Kralupy
Styrene and synthetic rubber production beside the Kralupy refinery.
Deza
Coal tar and crude benzol processing at Valašské Meziříčí.
Paramo
Bitumen and lubricant production at Pardubice.
Lovochemie
Nitrogen fertiliser production at Lovosice on the Elbe.

Industrial areas and sites

Litvínov and Záluží
Refinery, steam cracker and downstream polymer plants.
Kralupy nad Vltavou
Conversion refinery with a fluid catalytic cracker.
Neratovice
Chlor-alkali and PVC chemistry on the Elbe.
Valašské Meziříčí
Tar and benzol processing in the Zlín region.
Pardubice
Refining by-products, bitumen and lubricant blending.
Lovosice
Fertiliser production and river and rail loading.
Field notes · Czech Republic

More about Czech Republic that matters for portable equipment

Czech Republic: logistics and access

State operator MERO finished expanding the Transalpine pipeline at the end of 2024, delivering up to 8 million tonnes of oil a year, with the central oil depot at Nelahozeves as a key storage point.

Czech Republic: industry on the ground

The country has two refineries, both owned by Česká rafinérská, including the Litvínov refinery, so Litvínov and Kralupy are the best-known flammable-liquid processing sites.

Czech Republic: who works there

The Orlen Unipetrol group includes refineries and plants at Litvínov and Kralupy nad Vltavou, Paramo at Pardubice and Kolín, Spolana at Neratovice, and two research centres, and it is the only crude oil processor in the country.

Czech Republic: infrastructure

The Ingolstadt-Kralupy-Litvínov pipeline can bring crude oil from Germany and can be connected to the Transalpine pipeline, so crude arrives through pipeline terminals rather than seaports.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Czech Republic. The Czech route is entirely European: ATEX 2014/34/EU is transposed by nařízení vlády 116/2016 Sb., and a notified body certificate, EU declaration of conformity and CE marking suffice. Czech buyers often ask which body issued the certificate, since FTZÚ in Ostrava is notified body 1026. An IECEx route helps groups also working outside the EU. Certification is in progress.

The route · specification

Specifying an ATEX and IECEx mobile phone for Czech Republic

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Czech Republic

Frequently asked questions

Can we buy an ATEX and IECEx mobile phone in Czech Republic today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does an ATEX and IECEx mobile phone in Czech Republic cost?

There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which sites in Czech Republic does this cover?

The market guide for Czech Republic covers Litvínov and Záluží, Kralupy nad Vltavou, Neratovice, Valašské Meziříčí, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Are Czech refineries covered by ATEX rules for handheld devices?

The Czech Republic is an EU member, so ATEX Directive 2014/34/EU applies to equipment and employers zone workplaces under Directive 1999/92/EC. Refineries such as Litvínov typically also have internal device approval and permit-to-work procedures, so ask the HSE office before bringing phones in.

What language should Czech site documents be in?

Czech is the usual site language, and ATEX user instructions are typically expected in the local language of the destination. A Czech-language instruction sheet with the certificate pack often speeds up acceptance. Ask the operator whether it also accepts English documentation for contractors.

Why does the issuing notified body matter to Czech buyers?

FTZÚ in Ostrava-Radvanice is notified body 1026, and Czech engineers recognise it on an Ex certificate, so buyers often ask which body issued one before anything else. The certificate number, issuing body and marking string will be published for checking. No certificate exists yet, as certification is in progress.

Enquiry · Czech Republic

Ask about the IS-04Z1 for Czech Republic

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Czech Republic

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Czech Republic?

Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.