Angola: geography and layout
Cabinda is an exclave province of Angola, separated from the rest of the country by territory of the Democratic Republic of the Congo, which affects how people and equipment are moved there.
A Zone 1 / Zone 21 smartphone for crews on Angola's deepwater FPSOs, the Cabinda and Soyo onshore facilities, Angola LNG and the Luanda refinery. This page explains what to look for in an ATEX and IECEx mobile phone for Angola, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Angola: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Current position: certification in progress, nothing issued, launch targeted for Q4 2026. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | Angola: Luanda, Soyo, Zaire province, Cabinda and Malongo | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Angola. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The classified areas, operators and sites below are the ones covered in the SAMS Angola market guide.
Cabinda is an exclave province of Angola, separated from the rest of the country by territory of the Democratic Republic of the Congo, which affects how people and equipment are moved there.
Portuguese is Angola's official language, so permits, manuals and safety notices for local crews are normally expected in Portuguese.
The Instituto Angolano das Comunicações, INACOM, is the telecom regulator whose homologation is needed for wireless and telecom equipment sold in Angola.
Angola LNG Limited is owned by Sonangol, Chevron, TotalEnergies and Azule Energy, so the Soyo site combines several shareholders' operating practices.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In Angola. Operators in Angola apply the standards they use globally, so a procurement or HSE reviewer on an FPSO or at the Soyo plant would expect an IECEx Certificate of Conformity, with an ATEX certificate where the specification names the European directive. A dual route helps the marine contractors and FPSO owners who rotate between Angolan and other deepwater assets. Certification is in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
The market guide for Angola covers Luanda, Soyo, Zaire province, Cabinda and Malongo, Lobito, Benguela, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Large sites such as Angola LNG have several shareholders and an operating company that sets site HSE rules, which may follow one partner's standards. Confirm which standards and approved-equipment lists the operating company applies before you ship devices to Angola.
A single-train LNG plant typically has liquefaction, gas treatment, propane and butane storage, condensate handling and marine loading areas, all of which are normally classified as hazardous. The operator issues the zone drawings, so request them with the gas group and temperature class before choosing equipment.
It is designed for Zone 1 and Zone 21 duty, with a target marking of II 2 G Ex ib IIC T4, but certification is in progress and no certificate has been issued. Offshore use would depend on the operator's own equipment approval and the schedule of conditions. Confirm with the FPSO operator before any deck use.
Related guides for Angola and for Angola.
Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.
Tell us the zone, gas group and operator. We will send the datasheet and the certification schedule.