Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Pemex · ATEX and IECEx

ATEX and IECEx Mobile Phone for Pemex

Pemex is Mexico's state-owned oil company, founded in 1938, producing crude oil, natural gas, fuels and petrochemicals. It owns six refineries (Cadereyta, Madero, Minatitlan, Salamanca, Salina Cruz and Tula) and the newer Dos Bocas refinery, and operates offshore fields such as Cantarell in the Bay of Campeche. This page explains what to look for in an ATEX and IECEx mobile phone for Pemex, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Pemex, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceMobile Phone
RouteSpecification
WherePemex

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Pemex: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx mobile phone for Pemex

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesPemex: Offshore platforms, Refinery process units, Petrochemical plantsClassified by the site operator
Product · Mexico

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Mexico. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The organisation · Pemex

Working with Petroleos Mexicanos (Pemex): sites and classified areas

The main sites and the hazardous-area types a portable device is likely to meet at this organisation.

Sites and areas

  • Cantarell (Bay of Campeche)
  • Cadereyta (Nuevo Leon)
  • Madero (Tamaulipas)
  • Minatitlan (Veracruz)

Classified areas

  • Offshore platforms
  • Refinery process units
  • Petrochemical plants
Supplier approval · Pemex

Supplier registration at Pemex

Supplier registration and equipment approval are run by the organisation itself; confirm current requirements with its procurement and HSE teams. The Ex certificate and an organisation's own vendor or engineering approval are two separate timelines; SAMS is working towards both and holds neither today.

Field notes · Pemex

More about Pemex that matters for portable equipment

Pemex: projects and investment

In September 2021 Pemex and Braskem agreed a gas supply deal and a 400 million dollar ethane terminal at Laguna de Pajaritos in Coatzacoalcos, Veracruz, adding petrochemical handling in the south-east.

Pemex: background

Pemex was established by presidential decree on 7 June 1938, following the nationalisation of the oil industry that March, and has since been run as the Mexican state petroleum corporation.

Pemex: projects and investment

The Dos Bocas refinery plant opened in 2024 and was reported to be operating at 60% of capacity, transforming about 340,000 barrels a day of crude into fuels, so new-build units are being commissioned.

Pemex: background

Small quantities of oil were first refined into kerosene around 1876 near Tampico, showing that the Gulf coast oil area has a very long industrial history and ageing plant in places.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Pemex. A Pemex reviewer would expect certificate evidence before a handheld enters an offshore platform or a refinery process unit at sites such as Cadereyta, Tula or Salina Cruz. With international contractors and EPCs working on its refineries, a dual ATEX and IECEx route lets one product answer both families of paperwork. The IS-04Z1 is in certification and no certificate exists.

The route · specification

Specifying an ATEX and IECEx mobile phone for Pemex

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Pemex

Frequently asked questions

Can Pemex buy the IS-04Z1 today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an ATEX and IECEx mobile phone for Pemex cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

How does Pemex approve suppliers?

Supplier registration and equipment approval are run by the organisation itself; confirm current requirements with its procurement and HSE teams.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

How does the Gulf coast climate affect phones used on Pemex facilities?

Gulf of Mexico and Veracruz sites are typically hot, humid and salty, with heavy rain in the wet season. For handheld devices that means checking sealing, corrosion resistance and operating temperature, and asking the facility about its own environmental limits.

Which Pemex facilities usually have Zone 1 areas?

Typical Zone 1 and Zone 2 areas occur at refineries, gas processing and petrochemical plants, offshore platforms, LPG terminals and pipeline stations. Actual classification is facility-specific, so request area classification drawings from the operator before choosing portable equipment.

Do Pemex sites need Spanish-language device support?

In practice yes, since operators and maintenance crews work in Spanish. Check that the interface, MDM policies and documentation can be provided in Spanish before any pilot. The IS-04Z1 runs Android 16 with EMM/MDM support, but no certificate has been issued, and SAMS has appointed no Mexican distributor.

Enquiry · Pemex

Ask about the IS-04Z1 for Pemex, Mexico

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · Pemex

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Pemex?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.