Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
South Africa · ATEX and IECEx

ATEX and IECEx Cell Phone in South Africa

A Zone 1 / Zone 21 smartphone for crews at the Secunda and Sasolburg complexes, the Natref and Cape Town refineries, Mossel Bay, the fuel terminals and the surface plants of South African mining. This page explains what to look for in an ATEX and IECEx cell phone for South Africa, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for South Africa, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceCell Phone
RouteSpecification
WhereSouth Africa

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for South Africa: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Current position: certification in progress, nothing issued, launch targeted for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx cell phone for South Africa

Checks a reviewer should make, with the IS-04Z1 position
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesSouth Africa: Secunda, Mpumalanga, Sasolburg, Free State, Milnerton, Cape TownClassified by the site operator
Product · South Africa

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in South Africa. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · South Africa

Hazardous-area industry in South Africa

The main operators, industrial areas and sites that the SAMS South Africa market guide covers.

Operators, EPCs and contractors

Sasol
Synthetic fuels and chemicals at Secunda and Sasolburg
Natref
The inland refinery at Sasolburg
Astron Energy
The Cape Town refinery and fuel distribution
PetroSA
The gas to liquids complex at Mossel Bay
Transnet Pipelines
Fuel pipelines and terminals between Durban and Gauteng
Eskom
Coal-fired power stations and their coal handling plants

Industrial areas and sites

Secunda, Mpumalanga
Synthetic fuels and chemicals complex
Sasolburg, Free State
Chemicals production and the Natref refinery
Milnerton, Cape Town
The Astron Energy refinery
Mossel Bay, Western Cape
Gas to liquids complex and offshore gas
Durban
Fuel import terminals, tank farms and the chemical cluster
Richards Bay
Coal export terminal and bulk liquid storage
Field notes · South Africa

More about South Africa that matters for portable equipment

South Africa: industry on the ground

Secunda CTL, owned by Sasol, is the world's largest coal liquefaction plant, with capacity of 160,000 barrels a day from units built in 1980 and 1984, so synthetic fuel gas and liquids handling is extensive.

South Africa: geography and layout

Mining areas range from the Witwatersrand gold fields to Limpopo platinum mines such as Two Rivers at Steelpoort, so remote sites and deep underground workings are both common.

South Africa: rules and approvals

Electrical safety for some products is handled through SABS certificates of conformity and an NRCS letter of authority, which are separate from ICASA's radio approval.

South Africa: background

The 1886 discovery on the Witwatersrand started the gold rush that built Johannesburg's mining industry, and the country is still fifth in world gold production by one account.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In South Africa. A South African procurement or HSE reviewer at Sasol, Natref or Astron Energy would expect IECEx evidence first, because the sheet places IECEx first and a local Ex certificate after it under SANS 60079. A dual ATEX and IECEx route also helps international contractors and EPCs working on the large process sites. Nothing is issued yet.

The route · specification

Specifying an ATEX and IECEx cell phone for South Africa

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · South Africa

Frequently asked questions

Can we buy an ATEX and IECEx cell phone in South Africa today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does an ATEX and IECEx cell phone in South Africa cost?

There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which sites in South Africa does this cover?

The market guide for South Africa covers Secunda, Mpumalanga, Sasolburg, Free State, Milnerton, Cape Town, Mossel Bay, Western Cape, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Do mines in South Africa have different requirements from process plants?

Underground mines typically use Group I classification, with methane and coal-dust risks, while surface plants use Group II and III. SANS standards such as SANS 1515 cover mine gas-measuring equipment. Ask the mine or plant engineer which group and protection level the area drawing specifies before ordering.

Is there a national code for hazardous locations in South Africa?

Yes. The National Code of Practice for Electrical Machinery in Hazardous Locations sits under the Occupational Health and Safety Act 1993 and refers to SANS standards. Mines also have their own regulations and standards, so confirm which rules apply with the site's engineering and compliance team.

Can the IS-04Z1 be used underground in a South African mine?

No. Underground mining is equipment Group I, which is outside the scope of this device. The IS-04Z1 targets surface areas such as coal handling plants and process units using Zone 1 and Zone 21. Confirm the area and equipment group with the mine's safety officer.

Enquiry · South Africa

Ask about the IS-04Z1 for South Africa

Send the site, zone and gas group and roughly how many handsets. We reply by email with the datasheet and the certification schedule.

Enquiry · South Africa

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for South Africa?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.