United Kingdom: rules and approvals
Great Britain applies SI 2016 No. 1107, the UK version of the ATEX rules, so equipment for explosive atmospheres is assessed by UK approved bodies and carries UKCA marking and a body number.
The IS-04Z1 is an intrinsically safe Android smartphone designed for Zone 1 and Zone 21 work, from a North Sea deck to a gas governor kiosk at the end of a street. This page explains what to look for in a UKEX mobile phone for United Kingdom, and where the IS-04Z1 stands against that list today.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for United Kingdom: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| UK marking | UKCA mark and a UK approved body | In progress; not issued |
| Regulations | UKEX 2016 regulations | The applicable route in Great Britain |
| EU certificate | Does not cover Great Britain on its own | Separate UK route |
| Where it applies | United Kingdom: Aberdeen, St Fergus, Sullom Voe | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in United Kingdom. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
Operators and classified areas drawn from the SAMS United Kingdom market guide.
Great Britain applies SI 2016 No. 1107, the UK version of the ATEX rules, so equipment for explosive atmospheres is assessed by UK approved bodies and carries UKCA marking and a body number.
Historically most UK gas came from Morecambe Bay and the Southern North Sea off East Anglia and Lincolnshire, both now in decline, while oil comes mainly from the Central Graben of the North Sea.
Around 39 billion barrels of oil equivalent have been extracted from the UK Continental Shelf over four decades, and Brent crude from the British North Sea remains a major international price benchmark.
The UK government has legislated to keep recognising CE marking alongside UKCA for a range of product regulations, so check whether the route applies to your product category.
In Great Britain, equipment for potentially explosive atmospheres falls under the Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016 (UKEX), with UKCA marking and UK approved bodies. Northern Ireland continues to follow the EU regime. A device with an EU-type examination certificate still needs the UK route completed separately.
UKEX is one of the four routes in the IS-04Z1 certification programme. It is in progress and no UK certificate has been issued.
In United Kingdom. In the UK the regime is UKEX, a separate route from EU ATEX, and a reviewer at an installation or terminal would ask which approval the handset carries for the area. For the IS-04Z1 UKEX certification is in progress and no certificate exists, so a UK buyer can only review the schedule and datasheet today, with the duty holder deciding acceptance.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.
UKEX is part of the certification programme and is in progress. No UK certificate has been issued.
The market guide for United Kingdom covers Aberdeen, St Fergus, Sullom Voe, Grangemouth, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Offshore installations typically add their own permit-to-work, helicopter-transport and zone rules on top of UK law, and operators often keep lists of approved portable devices. Ask the duty holder or contractor for its approved-equipment procedure before sending devices offshore.
Equipment for Great Britain can be placed on the market under UKCA, using SI 2016 No. 1107 and a UK approved body, or under CE. Manufacturers usually keep both routes open if they sell in the EU too. Confirm the current labelling and importer details requirements with a UK approved body.
The 50 MP camera with PDAF is designed to give photographs sharp enough to act on, and GNSS can record where each was taken. Whether they are accepted as permit evidence is a matter for your duty holder and permit-to-work procedure.
More on United Kingdom, and on other places in United Kingdom.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.