Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
United States · intrinsically safe

Intrinsically Safe Cell Phone in United States

The IS-04Z1 is built for people who work inside classified locations at American refineries, gas plants, terminals and wellsites, and for the HSE and IT teams who decide what goes through the gate. If you are specifying an intrinsically safe cell phone for United States, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for United States, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicintrinsically safe
DeviceCell Phone
RouteSpecification
WhereUnited States

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for United States: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · intrinsically safe

Checklist: intrinsically safe cell phone for United States

Checks a reviewer should make, with the IS-04Z1 position
CheckWhat to look forIS-04Z1 today
Level of protectionia, ib or ic matched to the zoneib, for Zone 1
Entity parametersUo, Io and Po within the device limitsPublished with the certificate
AccessoriesChargers and cases certified with the deviceDefined at certification
Where it appliesUnited States: Permian Basin, Houston Ship Channel, Beaumont and Port ArthurClassified by the site operator
Product · United States

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in United States. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · United States

Hazardous-area industry in United States

The main operators, industrial areas and sites that the SAMS United States market guide covers.

Operators, EPCs and contractors

ExxonMobil
Baytown and Beaumont complexes, Permian acreage
Chevron
Permian operations, Pascagoula refinery, Anchor deepwater
Shell USA
Mars and Ursa hubs, Vito and Whale platforms
bp America
Thunder Horse, Whiting refinery, Kaskida development
ConocoPhillips
Permian and Eagle Ford, Alaska North Slope
Marathon Petroleum
Galveston Bay and Garyville refineries, MPLX midstream

Industrial areas and sites

Permian Basin
Midland and Delaware sub-basins, the largest US oil region
Houston Ship Channel
Baytown, Deer Park and Pasadena refining and chemicals
Beaumont and Port Arthur
Motiva, ExxonMobil and Valero refining on the Sabine
Lake Charles and Calcasieu
Refining, chemicals and LNG export in Louisiana
Baton Rouge corridor
Refining and chemical plants toward Plaquemine
Corpus Christi
Refining, crude export docks and LNG trains
Field notes · United States

More about United States that matters for portable equipment

United States: rules and approvals

Full certification in the US includes quarterly factory inspections, while field certification offers an alternative for custom or low-volume equipment already at an installation.

United States: rules and approvals

The National Electrical Code covers hazardous locations in Article 500 for the Class and Division system and in Articles 505 and 506 for the Zone system, as adopted by each state or authority.

United States: rules and approvals

The FCC regulates radio frequency devices between 9 kHz and 3000 GHz, and most radio-containing products must follow an equipment authorisation procedure before being marketed.

United States: rules and approvals

Zone-rated equipment in the US carries the AEx marking, for example Class I, Zone 0, AEx ia IIC T6, so a datasheet showing only ATEX or IECEx marks does not show US approval.

The term · intrinsically safe

What “intrinsically safe” means for a smartphone

Intrinsic safety limits the electrical and thermal energy in a circuit so that neither a spark nor a hot surface can ignite a gas or dust atmosphere, even when a fault occurs. The ib level, used for Zone 1, tolerates one fault. It is the usual way to make a handheld device that a worker carries continuously through a hazardous area.

The IS-04Z1 is designed on this principle for Zone 1 and Zone 21 (marking target II 2 G Ex ib IIC T4). Intrinsic safety is a design basis, not a certificate: certification is in progress and none has been issued yet.

In United States. Intrinsic safety suits pumper routes and compressor stations where hours separate charging points, and the long rounds at Gulf Coast refineries. A handheld that limits ignition energy lets a worker record, photograph and communicate with one hand free, which matters with gloves, fixed ladders and permit paperwork.

The route · specification

Specifying an intrinsically safe cell phone for United States

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · United States

Frequently asked questions

Can we buy an intrinsically safe cell phone in United States today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does an intrinsically safe cell phone in United States cost?

There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.

What does ‘intrinsically safe’ mean for the IS-04Z1?

The circuits are designed to limit energy so a spark or hot surface cannot ignite a gas or dust atmosphere, even with one fault (level ib, Zone 1). Certification of that design is in progress.

Which sites in United States does this cover?

The market guide for United States covers Permian Basin, Houston Ship Channel, Beaumont and Port Arthur, Lake Charles and Calcasieu, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Is IECEx or ATEX certification enough for US hazardous locations?

Not on its own. US workplace rules accept equipment approved by an OSHA-recognised NRTL and marked accordingly, and ATEX or IECEx certificates are not accepted in their place. Manufacturers usually need a separate US listing, so check the NRTL mark and the Class, Division or Zone marking on any device.

Do US sites use Class and Division or Zone classification?

Both exist. Article 500 of the National Electrical Code defines the Class and Division system, and Articles 505 and 506 define Zones. Many existing refineries and gas plants are still classified by Division, so confirm which system the area drawing uses before selecting equipment markings.

Can one handset suit both a Permian wellpad and a North Dakota gas plant?

IP68 sealing and a rugged build are aimed at August heat and January cold, and the 4,000 mAh battery at a shift away from the truck. The approved ambient range will come from the certificate, which is in progress, so confirm it for both extremes.

Enquiry · United States

Ask about the IS-04Z1 for United States

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · United States

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for United States?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.