Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Ireland · industrial

Industrial Smartphone in Ireland

The IS-04Z1 is an intrinsically safe Android handset designed for Zone 1 and Zone 21, aimed at the solvent suites and powder rooms of the Irish pharmaceutical cluster, and at the refinery, gas terminal and alumina plant that make up the rest. If you are specifying an industrial smartphone for Ireland, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Ireland, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicindustrial
DeviceSmartphone
RouteSpecification
WhereIreland

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Ireland: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Current position: certification in progress, nothing issued, launch targeted for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.

At a glance · industrial

Checklist: industrial smartphone for Ireland

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
Ingress protectionIP rating for dust and waterIP68 design
Fleet managementEMM and MDM supportAndroid 16 with EMM and MDM
Explosion protectionA separate certificate and markingIn progress; not issued
Where it appliesIreland: Ringaskiddy, Whitegate, Little Island and CarrigalineClassified by the site operator
Product · Ireland

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Ireland. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · Ireland

Where this applies in Ireland

The classified areas, operators and sites below are the ones covered in the SAMS Ireland market guide.

Operators, EPCs and contractors

Irving Oil
Whitegate refinery in Cork Harbour, the only refinery in the state.
Aughinish Alumina
The largest alumina refinery in Europe, on the Shannon Estuary.
Pfizer
Active ingredient and biologics plants at Ringaskiddy and Grange Castle.
MSD
Sites at Brinny, Ballydine, Carlow and Dunboyne.
Eli Lilly
Active ingredient manufacturing at Dunderrow near Kinsale.
Janssen Sciences Ireland
Biologics manufacturing at Ringaskiddy in Cork Harbour.

Industrial areas and sites

Ringaskiddy
Pharmaceutical and biologics plants on the lower harbour.
Whitegate
Refinery, crude jetty and product storage in Cork Harbour.
Little Island and Carrigaline
Chemical, pharmaceutical and industrial estates east of Cork.
Shannon Estuary
Aughinish, Foynes and the deep-water industrial berths.
Grange Castle and Clondalkin
Dublin biopharma campuses and process plants.
Bellanaboy
Corrib gas terminal and pipeline landfall in north Mayo.
Field notes · Ireland

More about Ireland that matters for portable equipment

Ireland: infrastructure

Moneypoint on the Shannon estuary, commissioned 1985-1987 and Ireland's largest power station at 915 MW, stopped burning coal in June 2025 and is due to run as a heavy-oil back-up plant until 2029.

Ireland: who works there

Vermilion Energy became operator of the Corrib project in 2018 and the majority owner in 2021, so contractor induction and device approval at Bellanaboy follow that operator's procedures.

Ireland: rules and approvals

Directive 2014/34/EU replaced the earlier 94/9/EC equipment directive and became mandatory for manufacturers on 20 April 2016, so older Ex devices may carry earlier markings.

Ireland: background

The Corrib field was discovered in 1996 and was the first reported commercial gas discovery in Ireland since the Kinsale Head field in 1971, which shows how few upstream gas sites exist.

The term · industrial

What “industrial” means for a smartphone

“Industrial” describes a phone built for plant conditions: sealed, drop-resistant and manageable at fleet scale through Android Enterprise. It does not by itself mean the phone may enter a classified area. Only a device with a valid explosion-protection certificate and marking may do that.

The IS-04Z1 is designed to be both an industrial Android phone (IP68, 4,000 mAh battery, 50 MP camera, Android 16 with EMM and MDM support) and an intrinsically safe one. Its explosion-protection certificates are in progress and have not been issued.

In Ireland. Irish plants run many contractors alongside site staff, so EMM or MDM enrolment helps provision devices by project. The IS-04Z1 is designed for managed deployment. Pharmaceutical sites often have strict IT and data policy, so connectivity, charging in safe areas and device approval should be agreed with the site team.

The route · specification

Specifying an industrial smartphone for Ireland

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Ireland

Frequently asked questions

Can we buy an industrial smartphone in Ireland today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does an industrial smartphone in Ireland cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Is the IS-04Z1 an industrial phone as well as an Ex phone?

Yes by design: IP68 sealing, a 4,000 mAh battery, a 50 MP camera and Android 16 with EMM and MDM support. The explosion-protection certificates are separate and still in progress.

Which sites in Ireland does this cover?

The market guide for Ireland covers Ringaskiddy, Whitegate, Little Island and Carrigaline, Shannon Estuary, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Where is Ireland's main hazardous-area gas site?

The Corrib gas field off County Mayo, with its onshore processing plant at Bellanaboy, is Ireland's only domestic gas production source. Other hazardous areas include fuel terminals, power stations and chemical or pharmaceutical plants. Request the operator's zone drawings before planning device use.

Who approves contractors' devices at Bellanaboy?

The project operator, currently Vermilion Energy, sets contractor and equipment requirements for the Corrib onshore plant, normally through its HSE team. Contact the site HSE office for the current induction, device registration and certificate requirements before travelling.

Can a handset be used in a pharmaceutical solvent suite?

That depends on the zone, gas group and the site's rules. The device would need a marking suited to the classified room, and the site may add its own IT, cleaning and data rules. Ask the site's HSE team to review the evidence before bringing any device in.

Enquiry · Ireland

Ask about the IS-04Z1 for Ireland

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · Ireland

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Ireland?

Name the site and the operator and we will send what is available before launch.