Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
United Kingdom · hazardous area

Hazardous Area Mobile Phone in United Kingdom

The IS-04Z1 is an intrinsically safe Android smartphone designed for Zone 1 and Zone 21 work, from a North Sea deck to a gas governor kiosk at the end of a street. This page explains what to look for in a hazardous area mobile phone for United Kingdom, and where the IS-04Z1 stands against that list today.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for United Kingdom, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topichazardous area
DeviceMobile Phone
RouteSpecification
WhereUnited Kingdom

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for United Kingdom: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.

At a glance · hazardous area

Checklist: hazardous area mobile phone for United Kingdom

Specification checklist against the IS-04Z1 today
CheckWhat to look forIS-04Z1 today
Zone0, 1 or 2 for gas; 20, 21 or 22 for dustDesigned for Zone 1 and Zone 21
Gas groupIIA, IIB or IICIIC (target)
Area drawingThe operator's own classification drawingDecided by the site operator
Where it appliesUnited Kingdom: Aberdeen, St Fergus, Sullom VoeClassified by the site operator
Product · United Kingdom

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in United Kingdom. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · United Kingdom

Hazardous-area industry in United Kingdom

The main operators, industrial areas and sites that the SAMS United Kingdom market guide covers.

Operators, EPCs and contractors

Harbour Energy
One of the largest producers on the UK continental shelf.
Adura
Shell and Equinor joint venture with interests in Mariner, Clair, Shearwater and Buzzard (operators vary by field).
Ithaca Energy
Operator and partner across central and northern North Sea hubs.
EnQuest
Operates Magnus and the Sullom Voe terminal.
Serica Energy
Operates the Bruce, Keith and Rhum fields.
Wood
Aberdeen engineering, maintenance and shutdown contractor.

Industrial areas and sites

Aberdeen
Supply base, heliports and the offshore contractor market.
St Fergus
Reception terminal for northern North Sea gas pipelines.
Sullom Voe
Shetland oil and gas terminal with export jetties.
Grangemouth
INEOS petrochemical complex and the fuels import terminal.
Fawley
ExxonMobil refinery and petrochemicals on Southampton Water.
Stanlow
Refinery and the Mersey chemical corridor.
Field notes · United Kingdom

More about United Kingdom that matters for portable equipment

United Kingdom: industry on the ground

UK crude oil and condensate production had fallen to about 630,000 barrels a day by 2024, so much of the current work is maintenance, life extension and decommissioning of mature installations.

United Kingdom: industry on the ground

About 98 per cent of UK oil and gas production comes from offshore fields, and the services industry in Aberdeen has been a leader in offshore technology.

United Kingdom: rules and approvals

The Dangerous Substances and Explosive Atmospheres Regulations 2002 require employers to identify and classify areas where explosive atmospheres may occur and to avoid ignition sources from unprotected equipment in them.

United Kingdom: rules and approvals

Since 1 October 2024 CE marking has been recognised in Great Britain without an end date, so ATEX-certified products can be sold there without UKCA, while Northern Ireland still requires CE.

The term · hazardous area

What “hazardous area” means for a smartphone

A hazardous area is a place where flammable gas, vapour or combustible dust may be present. Standards divide these into zones: Zones 0, 1 and 2 for gas and vapour, and Zones 20, 21 and 22 for dust. Zone 1 and Zone 21 are the tier where an explosive atmosphere is likely to occur in normal operation, which is where the IS-04Z1 is designed to work. Anything carried in must be marked for the zone, gas group and temperature class of the area.

No certificate has been issued for the IS-04Z1 yet, so it must not be taken into a classified area until the certificate covering it exists and the site operator has accepted it.

In United Kingdom. UK classified areas fall into two patterns: a few large installations with formal permit systems, offshore and downstream, and inland Zone 1 and Zone 2 work spread thinly across gas networks, water and waste sites staffed by one or two people. The duty holder classifies each area. SAMS does not classify any area.

The route · specification

Specifying a hazardous area mobile phone for United Kingdom

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · United Kingdom

Frequently asked questions

Can we buy a hazardous area mobile phone in United Kingdom today?

No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.

What does a hazardous area mobile phone in United Kingdom cost?

There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.

Which hazardous areas is the IS-04Z1 designed for?

Zone 1 and Zone 21 (gas and dust) with gas group IIC and temperature class T4, subject to certification. It must not be used in a classified area before its certificate is issued and the site has accepted it.

Which sites in United Kingdom does this cover?

The market guide for United Kingdom covers Aberdeen, St Fergus, Sullom Voe, Grangemouth, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

What does DSEAR mean for choosing a phone for UK plants?

DSEAR places duties on employers to classify areas where explosive atmospheres may occur and to avoid ignition sources from unprotected equipment. A site will therefore expect devices used in classified areas to be suitable for the zone, gas group and temperature class stated in its area classification records.

Is CE-marked ATEX equipment accepted in Great Britain?

Yes. Since 1 October 2024 CE marking has been recognised in Great Britain without an end date, so an ATEX-certified product can be sold there without UKCA, although a UKCA route with a UK approved body also exists. Northern Ireland still requires CE. Check the current rules before shipping.

How does the IS-04Z1 cope with patchy coverage on a UK platform or rural site?

It combines 4G LTE, Wi-Fi and four-constellation GNSS to hold a position and a connection where one network is not enough. Actual coverage depends on the site, so test the unit on your own route before relying on it.

Enquiry · United Kingdom

Ask about the IS-04Z1 for United Kingdom

Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.

Enquiry · United Kingdom

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for United Kingdom?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.