China: geography and layout
China's land-based oil resources are mostly in the north, with large fields at Daqing, Shengli, Liaohe, Karamay and Dagang, so cold-climate and arid-climate sites are both common.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in China every shift: oilfield and refinery operators, coal-mining safety officers, petrochemical engineers, and the HSE and telecoms teams who equip them. This page sets out how an explosion proof mobile phone supply route to China will work for the IS-04Z1, and what is and is not available before launch.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. An explosion proof mobile phone for China cannot be bought yet: the SAMS IS-04Z1 is pre-launch (certification in progress, no certificate issued), and the datasheet, certification schedule and safe-area evaluation units are available now.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. An operator's own vendor approval is a separate step. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Protection concept | Flameproof (Ex d) or intrinsic safety (Ex i) | Intrinsic safety, level ib |
| Zone suitability | Zone 1 gas and Zone 21 dust | Design target for Zone 1 and 21 |
| Certificate | Number, issuing body and schedule of conditions | In progress; not issued |
| Where it applies | China: Zhoushan / Ningbo, Maoming, Shanxi | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in China. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS China market guide covers.
China's land-based oil resources are mostly in the north, with large fields at Daqing, Shengli, Liaohe, Karamay and Dagang, so cold-climate and arid-climate sites are both common.
The current implementing rule is CNCA-C23-01:2024, in force since 1 May 2024, and certification has been to the 2021 editions of GB/T 3836 since 1 May 2022.
GB 3836.15-2024 on design, selection and erection and GB 3836.16-2024 on inspection and maintenance took effect as mandatory national standards on 1 August 2025, governing installations rather than product certification.
Phones also need the MIIT network access licence (NAL) and SRRC radio approval; the NAL is described as compulsory, valid for three years, with local testing and a local representative required.
“Explosion proof” is the phrase most buyers use for equipment that may be taken into a classified hazardous area. Strictly, it covers several protection concepts: a flameproof enclosure (Ex d) contains an internal explosion, while intrinsic safety (Ex i) limits electrical energy so that an ignition cannot start. Phones are normally intrinsically safe, because a flameproof handset would be too heavy to carry all shift.
The IS-04Z1 uses intrinsic safety, with a marking target of Ex ib IIC T4, and is designed for Zone 1 and Zone 21. It is pre-launch, certification is in progress and no certificate has been issued.
In China. Explosion proof is the everyday phrase, but a coal mine and a coastal petrochemical plant need different thinking. Flameproof Ex d suits much fixed mining equipment; the IS-04Z1 uses intrinsic safety to limit energy in a handheld. It is designed for Zone 1 gas and Zone 21 dust, not underground classification. Operators classify areas, not SAMS.
Nothing can be bought for China today: the IS-04Z1 is pre-launch, and SAMS will supply end users through authorised distributors once certificates exist. What a buyer can do now is take the specification, ask for the written certification schedule and arrange a safe-area evaluation, so that the right local channel contacts you at launch.
The technical specification, marking target and conditions of use, sent by email.
Which certificates are in progress, in what order, and what is still to be confirmed.
Evaluation units can be used for connectivity, MDM enrolment and workflow testing outside classified areas.
Tell us the site, zone, gas group and quantity so the right authorised distributor can contact you.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
It is intrinsically safe (marking target Ex ib IIC T4), which is the usual way to make a phone for hazardous areas. It is not a flameproof (Ex d) design, and certification is still in progress.
The market guide for China covers Shanxi, Shaanxi and Inner Mongolia, Daqing, Shengli oilfield, among others. Site-level pages are linked below.
Through authorised distributors once certificates exist. Until then SAMS can send the datasheet and certification schedule and arrange safe-area evaluation units.
Fields such as Daqing in the north-east have cold winters, while Karamay and other north-western fields are arid, so a wide operating temperature range and dust ingress protection are sensible. Confirm site limits with the operator before deployment.
An IECEx test report is reported as recognised as test evidence, but it does not replace the CCC certificate, and ATEX certificates are not accepted. Plan a separate CCC programme with a designated body, using the IECEx test work to reduce duplication where permitted.
The design covers Zone 1 gas and Zone 21 dust together, matching the combined methane and coal dust exposure, but certification is in progress and no certificate exists. Underground mining is a distinct classification regime, so a mine operator would need to confirm suitability. Check requirements with the mine safety authority.
More on China, and on other places in China.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.