China: geography and layout
China's land-based oil resources are mostly in the north, with large fields at Daqing, Shengli, Liaohe, Karamay and Dagang, so cold-climate and arid-climate sites are both common.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in China every shift: oilfield and refinery operators, coal-mining safety officers, petrochemical engineers, and the HSE and telecoms teams who equip them. If you are specifying an Ex-proof smartphone for China, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for China: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Status: pre-launch. IECEx, ATEX, UKEX and NEC 500 certification is in progress and no certificate has been issued; launch is planned for Q4 2026. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Ex marking | Group, category, protection concept, gas group, temperature class | II 2 G Ex ib IIC T4 (target) |
| Gas group | IIA, IIB or IIC matched to the area drawing | IIC (target) |
| Temperature class | T-class below the ignition temperature of the gas | T4, 135 °C (target) |
| Where it applies | China: Shanxi, Shaanxi and Inner Mongolia, Daqing | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in China. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS China market guide covers.
China's land-based oil resources are mostly in the north, with large fields at Daqing, Shengli, Liaohe, Karamay and Dagang, so cold-climate and arid-climate sites are both common.
The current implementing rule is CNCA-C23-01:2024, in force since 1 May 2024, and certification has been to the 2021 editions of GB/T 3836 since 1 May 2022.
GB 3836.15-2024 on design, selection and erection and GB 3836.16-2024 on inspection and maintenance took effect as mandatory national standards on 1 August 2025, governing installations rather than product certification.
Phones also need the MIIT network access licence (NAL) and SRRC radio approval; the NAL is described as compulsory, valid for three years, with local testing and a local representative required.
“Ex-proof” is shorthand for equipment carrying an explosion-protection marking (the Ex mark) that matches the area it enters. The marking states the protection concept, gas or dust group and temperature class, and it must be backed by a certificate issued by a recognised body, so a phone described as Ex-proof should come with a certificate number you can check.
The IS-04Z1 is designed to carry the marking II 2 G Ex ib IIC T4. That is a target: certification is in progress, no certificate has been issued, and SAMS will publish the certificate numbers when they exist.
In China. A marking check in China would cover the NEPSI mark alongside the IECEx marking, then gas group, T class and ambient range. Underground coal combines methane and coal dust in one environment, and the design targets Zone 1 gas and Zone 21 dust together. The target marking is II 2 G Ex ib IIC T4.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.
There is no list price yet. SAMS gives indicative pre-launch pricing in writing, against a stated quantity and site, and does not commit to a lead time before certification completes.
The marking target is II 2 G Ex ib IIC T4. It becomes a marking only when the certificate is issued; until then it is a design target.
The market guide for China covers Shanxi, Shaanxi and Inner Mongolia, Daqing, Shengli oilfield, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Fields such as Daqing in the north-east have cold winters, while Karamay and other north-western fields are arid, so a wide operating temperature range and dust ingress protection are sensible. Confirm site limits with the operator before deployment.
An IECEx test report is reported as recognised as test evidence, but it does not replace the CCC certificate, and ATEX certificates are not accepted. Plan a separate CCC programme with a designated body, using the IECEx test work to reduce duplication where permitted.
The design covers Zone 1 gas and Zone 21 dust together, matching the combined methane and coal dust exposure, but certification is in progress and no certificate exists. Underground mining is a distinct classification regime, so a mine operator would need to confirm suitability. Check requirements with the mine safety authority.
Other guides for China, other places in China, and the pages behind them.
Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.