Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
South Korea · ATEX and IECEx

ATEX and IECEx Smartphone in South Korea

The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in South Korea every shift: refinery and petrochemical-complex operators at Ulsan and Yeosu, shipyard tank engineers, and the HSE and telecoms teams who equip them. If you are specifying an ATEX and IECEx smartphone for South Korea, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for South Korea, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceSmartphone
RouteSpecification
WhereSouth Korea

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for South Korea: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

For the record, no certificate exists for the IS-04Z1 today. The programme is under way ahead of a Q4 2026 launch. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx smartphone for South Korea

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesSouth Korea: Ulsan, Yeosu, DaesanClassified by the site operator
Product · South Korea

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in South Korea. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The market · South Korea

Hazardous-area industry in South Korea

The main operators, industrial areas and sites that the SAMS South Korea market guide covers.

Operators, EPCs and contractors

SK Energy
SK Innovation’s refining arm, based at Ulsan
GS Caltex
Major refiner and petrochemical producer at Yeosu
S-Oil
Saudi Aramco-affiliated refiner based at Onsan, Ulsan
Hyundai Oilbank
Refining and petrochemical operations at Daesan
Lotte Chemical
Major petrochemical producer across multiple complexes
Hyundai Heavy Industries
The world’s largest shipbuilder, with LNG and tanker construction at Ulsan

Industrial areas and sites

Ulsan
Korea’s largest industrial complex: refining, petrochemicals and shipbuilding together
Yeosu
Major petrochemical complex on the south coast
Daesan
Petrochemical complex on the west coast
Onsan
Refining and non-ferrous smelting zone within greater Ulsan
Geoje
Major shipbuilding yards constructing LNG carriers and offshore platforms
Field notes · South Korea

More about South Korea that matters for portable equipment

South Korea: industry on the ground

Ulsan is the industrial centre of the south-east, hosting the world's largest car assembly plant, the world's largest shipyard and the world's third-largest oil refinery, which makes it a dense mix of process and manufacturing hazards.

South Korea: geography and layout

The country has no proven oil reserves; the Donghae-1 gas field produced between 2004 and 2021 and east-coast gas exploration started in 2024, so most hazardous-area work is downstream rather than upstream.

South Korea: infrastructure

Thermal generation provides more than two thirds of electricity and nuclear power most of the rest; the first plant, Kori near Busan, opened in 1977, so large plant outages involve many contractors.

South Korea: industry on the ground

GS Caltex concentrates its refining and petrochemical plants at the Yeosu Complex, covering about 6 million square metres, with 800,000 barrels per stream day of capacity and Korea's largest heavy oil upgrading unit at 275,000 barrels a day.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In South Korea. A Korean HSE or procurement reviewer at Ulsan, Yeosu or Daesan would expect KOSHA and IECEx evidence, as the sheet lists both in progress. ATEX alongside IECEx helps the international contractors and shipyard customers who work to those schemes. No certificate has been issued for the IS-04Z1, so a review today covers the schedule only.

The route · specification

Specifying an ATEX and IECEx smartphone for South Korea

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · South Korea

Frequently asked questions

Can we buy an ATEX and IECEx smartphone in South Korea today?

Not today. Until the certificates are issued the IS-04Z1 stays out of classified areas, and until launch there is nothing to purchase. You can ask for the datasheet and the certification schedule, or book a safe-area evaluation unit.

What does an ATEX and IECEx smartphone in South Korea cost?

SAMS has not published a price. Any figure you are offered for an uncertified Ex phone should be treated with caution; written indicative pricing is available for a defined quantity and site.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which sites in South Korea does this cover?

The market guide for South Korea covers Ulsan, Yeosu, Daesan, Onsan, among others. Site-level pages are linked below.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

Where are the main hazardous-area clusters in South Korea?

Ulsan is the best-known, with a very large refinery, petrochemical works and shipyard, and the country's LNG import terminals are another cluster. Because supply is almost entirely imported, fuel storage and terminal sites are central; confirm each site's classification with its operator.

Do intrinsically safe phones need Korean certification for use on site?

Operators may ask for Korea's own national certification alongside, or instead of, international certificates such as IECEx or ATEX. Requirements differ by site and contractor, so ask the operator's safety team which marking and approvals it accepts before ordering devices.

Is the IS-04Z1 meant for shipyard tank work at Geoje?

The same Zone 1 specification is designed to cover tank-entry and marine-fuel hazards alongside refinery risk. Certification is in progress and no certificate exists. Confirm the exact area, gas group and permit rules with the yard's safety officer before any use.

Enquiry · South Korea

Ask about the IS-04Z1 for South Korea

Share the site details and quantity. You will get the datasheet and the certification schedule back by email; pricing is indicative only until launch.

Enquiry · South Korea

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for South Korea?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.