China: geography and layout
China's land-based oil resources are mostly in the north, with large fields at Daqing, Shengli, Liaohe, Karamay and Dagang, so cold-climate and arid-climate sites are both common.
The IS-04Z1 is an intrinsically safe handset for people who cross into classified areas in China every shift: oilfield and refinery operators, coal-mining safety officers, petrochemical engineers, and the HSE and telecoms teams who equip them. If you are specifying an ATEX and IECEx smartphone for China, this page covers the markings, the approvals and the current certification status of the IS-04Z1.
Pre-launch · certification in progress · Launching Q4 2026
Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for China: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.
Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. Operator approval runs on its own timeline. Certification status. Place facts reviewed October 2026.
| Check | What to look for | IS-04Z1 today |
|---|---|---|
| Marking | II 2 G Ex ib IIC T4 on the rating plate | Design target; not yet marked |
| EU-type examination certificate | Notified body number and certificate ID | In progress with TÜV; not issued |
| IECEx certificate of conformity | Number listed on the IECEx online register | In progress; not issued |
| Where it applies | China: Shanxi, Shaanxi and Inner Mongolia, Daqing | Classified by the site operator |

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in China. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.
The main operators, industrial areas and sites that the SAMS China market guide covers.
China's land-based oil resources are mostly in the north, with large fields at Daqing, Shengli, Liaohe, Karamay and Dagang, so cold-climate and arid-climate sites are both common.
The current implementing rule is CNCA-C23-01:2024, in force since 1 May 2024, and certification has been to the 2021 editions of GB/T 3836 since 1 May 2022.
GB 3836.15-2024 on design, selection and erection and GB 3836.16-2024 on inspection and maintenance took effect as mandatory national standards on 1 August 2025, governing installations rather than product certification.
Phones also need the MIIT network access licence (NAL) and SRRC radio approval; the NAL is described as compulsory, valid for three years, with local testing and a local representative required.
ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.
For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.
In China. In China NEPSI is the Ex certification authority, and the technical evidence behind it is typically aligned with an IECEx Certificate of Conformity, so a reviewer at Sinopec or PetroChina would ask for the NEPSI certificate first. An IECEx and ATEX dual route helps foreign contractors on petrochemical projects. All certification is in progress.
A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.
No. Nothing can be bought or taken into a classified area today: certification is in progress and launch is planned for Q4 2026. What is available now is the datasheet, the written certification schedule and evaluation units for safe-area use.
No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.
Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.
The market guide for China covers Shanxi, Shaanxi and Inner Mongolia, Daqing, Shengli oilfield, among others. Site-level pages are linked below.
Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.
Fields such as Daqing in the north-east have cold winters, while Karamay and other north-western fields are arid, so a wide operating temperature range and dust ingress protection are sensible. Confirm site limits with the operator before deployment.
An IECEx test report is reported as recognised as test evidence, but it does not replace the CCC certificate, and ATEX certificates are not accepted. Plan a separate CCC programme with a designated body, using the IECEx test work to reduce duplication where permitted.
The design covers Zone 1 gas and Zone 21 dust together, matching the combined methane and coal dust exposure, but certification is in progress and no certificate exists. Underground mining is a distinct classification regime, so a mine operator would need to confirm suitability. Check requirements with the mine safety authority.
Related guides for China and for China.
Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.
Send the zone and gas group of your site and we will reply with the datasheet and schedule.