Skip to content
Certification In Progress · Launching Q4 2026 Become a Distributor
Certification In Progress · Launching Q4 2026 Product Certifications Industries Blog About Contact Become a Distributor
Villahermosa · ATEX and IECEx

ATEX and IECEx Mobile Phone in Villahermosa

Villahermosa is the capital of Tabasco and is known as the energy city of Mexico because of its role in southern oil and gas. Fields such as Ogarrio lie nearby and the Olmeca refinery at Dos Bocas is in the state, so many hazardous-area workers are based here. If you are specifying an ATEX and IECEx mobile phone for Villahermosa, this page covers the markings, the approvals and the current certification status of the IS-04Z1.

Pre-launch · certification in progress · Launching Q4 2026

SAMS IS-04Z1 intrinsically safe smartphone for Villahermosa, front view
Marking targetEx ib IIC T4Intrinsic safety, Zone 1 / 21 design target · certification in progress
AvailabilityQ4 2026via authorised distributors
Search topicATEX and IECEx
DeviceMobile Phone
RouteSpecification
WhereVillahermosa

Short answer. The SAMS IS-04Z1 is the intrinsically safe smartphone covered here for Villahermosa: pre-launch, designed for Zone 1 and Zone 21 (marking target Ex ib IIC T4), with certification in progress and no certificate issued.

Where things stand: the IS-04Z1 has not launched, and none of its four certification routes has produced a certificate yet. A buyer's engineering review is separate from the certificate. Certification status. Place facts reviewed October 2026.

At a glance · ATEX and IECEx

Checklist: ATEX and IECEx mobile phone for Villahermosa

What to check, and where the IS-04Z1 stands today
CheckWhat to look forIS-04Z1 today
MarkingII 2 G Ex ib IIC T4 on the rating plateDesign target; not yet marked
EU-type examination certificateNotified body number and certificate IDIn progress with TÜV; not issued
IECEx certificate of conformityNumber listed on the IECEx online registerIn progress; not issued
Where it appliesVillahermosa: Oil and gas production facilities, Refinery process units (Olmeca, Dos Bocas), Pipeline and storage facilitiesClassified by the site operator
Product · Villahermosa

The product behind this search: the SAMS IS-04Z1.

SAMS IS-04Z1 explosion proof mobile phone, front view

SAMS IS-04Z1

An intrinsically safe Android smartphone designed for Zone 1 and Zone 21 hazardous areas in Villahermosa. It is pre-launch: IECEx, ATEX and NEC 500 certification is in progress ahead of the Q4 2026 launch.

  • IP68 sealed
  • 4,000 mAh battery
  • 50 MP camera
  • Android 16
  • Zone 1 / Zone 21 design target
The site · Villahermosa

Villahermosa at a glance: who is there, what is classified

A short profile of the site and the kinds of classified area that matter for portable equipment.

Operators and companies on site

  • Pemex
  • Oilfield service contractors

Classified areas to expect

  • Oil and gas production facilities
  • Refinery process units (Olmeca, Dos Bocas)
  • Pipeline and storage facilities
Local conditions · Villahermosa

Site conditions at Villahermosa: what wears and what limits equipment

Regional hub

Offices, warehouses and service firms concentrate in the city, with fields and plants spread across the surrounding lowlands.

Refinery nearby

The Olmeca refinery at Dos Bocas, Paraiso, marked two years of operation in August 2026, with capital spending budgeted for 2026.

Field notes · Villahermosa

More about Villahermosa that matters for portable equipment

Villahermosa: geography and layout

Villahermosa has several lagoons, the largest being La Laguna de las Ilusiones, so water and wetlands influence site layout and access across the surrounding lowlands.

Villahermosa: geography and layout

The city is about 50 km south of the Gulf coast and 904 km southeast of Mexico City, between the Grijalva and Carrizal rivers, at an average elevation of about 10 m above sea level.

Villahermosa: logistics and access

Villahermosa's airport was inaugurated on 2 May 1979, has a single 2,200 m runway and has offered flights to Houston and Panama City aimed largely at the oil industry.

Villahermosa: industry on the ground

Villahermosa, capital of Tabasco, has become a hub for oil and gas operations in southern Mexico, alongside its agricultural base of cacao, sugarcane, bananas and rice.

The term · ATEX and IECEx

What “ATEX and IECEx” means for a smartphone

ATEX is the European legal framework for equipment used in explosive atmospheres (Directive 2014/34/EU). IECEx is the international certification scheme built on the IEC 60079 standards. Buyers outside Europe often ask for both: an IECEx certificate is the technical evidence most national regimes build on, while ATEX is the legal route into the European market.

For the IS-04Z1 both routes are in progress with TÜV in Germany and neither certificate has been issued. The marking target is II 2 G Ex ib IIC T4: equipment Group II (surface industry), Category 2 (Zone 1 gas), protection concept ib (intrinsic safety), gas group IIC and temperature class T4.

In Villahermosa. Villahermosa is called the energy city of Mexico, and Pemex plus a wide set of oilfield service contractors are based there. Reviewers deal with contractor packs that may carry ATEX, IECEx or both. A dual route helps international contractors working on fields and refinery projects across Tabasco. The IS-04Z1 has no certificate yet, as certification is in progress.

The route · specification

Specifying an ATEX and IECEx mobile phone for Villahermosa

A short checklist for anyone writing or reviewing the specification, with the IS-04Z1 status against each point.

Check on the paper

Marking
Equipment group, category, protection concept, gas group and temperature class, matched to the area drawing.
Certificate and schedule
A certificate number, issuing body and the schedule of conditions, not a brochure claim.
Standards edition
The IEC 60079 or national standard edition the certificate was issued against.

Check for the IS-04Z1

Marking target
II 2 G Ex ib IIC T4: a target, not yet a certificate.
Certificate status
IECEx, ATEX, UKEX and NEC 500 in progress; none issued.
Operator approval
Separate from the certificate and handled with the site operator.
Questions · Villahermosa

Frequently asked questions

Can we buy an ATEX and IECEx mobile phone in Villahermosa today?

Not yet. The IS-04Z1 is pre-launch and its certification is still in progress ahead of a Q4 2026 launch. No unit goes into a classified area before the certificate covering it exists. The datasheet, the certification schedule and safe-area evaluation units are available now.

What does an ATEX and IECEx mobile phone in Villahermosa cost?

No price is published. While certification is in progress there is no list price and no committed lead time, and a supplier quoting a firm figure for an uncertified Ex handset is promising something it cannot stand behind. Indicative pre-launch pricing is issued in writing against a stated quantity and site.

Is the IS-04Z1 ATEX and IECEx certified?

Not yet. Both routes are in progress with TÜV in Germany and no certificate has been issued. Any listing that says otherwise is wrong.

Which areas at Villahermosa would use it?

Likely candidates are oil and gas production facilities, refinery process units (olmeca, dos bocas), pipeline and storage facilities. Which areas are classified, and to what zone, is set by the site operator's own area classification drawings.

Is intrinsically safe the same as explosion proof?

Not exactly. Explosion proof is a broad everyday term; intrinsic safety is one protection concept, which limits energy so ignition cannot occur. Flameproof (Ex d) is a different concept that contains an explosion. The IS-04Z1 is intrinsically safe by design.

What oil and gas facilities are near Villahermosa?

It is described as a hub for southern Mexico's oil and gas operations, with offices, service firms and field facilities across Tabasco. Confirm the specific facility and operator, since classified areas are defined site by site.

How hot does it get for equipment in Villahermosa?

Spring and summer temperatures can exceed 40 C with high humidity, so devices need good thermal margins and a suitable temperature class. Confirm operator guidance on outdoor equipment and keep devices out of direct sun.

How does flooding risk affect equipment choice?

Low-lying sites need weather planning, given a record flood in 2007 and a hot, wet climate. IP68 is designed to withstand water immersion and dust, but it is not explosion protection. Check the certified ambient range and store devices dry between shifts.

Enquiry · Villahermosa

Ask about the IS-04Z1 for Villahermosa, Mexico

Tell us what you need to equip and where. The SAMS team answers by email with the datasheet and where each certification route stands.

Enquiry · Villahermosa

Please enter your name.
Please enter your company name.
Enter a valid email address.
Please enter your target market.
Please select one.

Launching Q4 2026

Planning for Villahermosa?

Send the zone and gas group of your site and we will reply with the datasheet and schedule.